9 - 96
MELSEC-Q
9 MAJOR POSITIONING CONTROL
Note: Operation runs at speed 1 when a reference axis speed is less than 1 as
a result of speed limit.
In addition, when a bias speed is set, it will be the minimum speed.
(5) An error "No command speed" (error code: 503) occurs if a current speed (-1)
is set in " Da.8 Command speed".
(6) The software stroke limit check is not carried out when the control unit is set to
"degree".
Positioning data setting examples
[Setting examples when the reference axis and interpolation axis are designated
as axes 1 and 2, respectively.]
The following table shows the setting examples when "2-axis speed control
(forward run: speed 2)" is set in the positioning data No. 1 of axis 1 (reference
axis).
Axis
Setting item
Axis 1
(reference
axis) setting
example
Axis 2
(interpolation
axis) setting
example
Setting details
Axis
1 Po
sitioning
data
N
o.
1
Da.1 Operation pattern
Positioning
complete
–
Setting other than "Positioning complete" is not possible in
speed control.
Da.2 Control system
Forward run
speed 2
–
Set 2-axis speed control.
Da.3 Acceleration time
No.
1 –
Designate the value set in " Pr.25 Acceleration time 1"
as the acceleration time at start.
Da.4 Deceleration time
No.
0 –
Designate the value set in " Pr.10 Deceleration time 0"
as the deceleration time at deceleration.
Da.5 Axis to be
interpolated
Axis 2
–
Set the axis to be interpolated (partner axis).
If the self-axis is set, an error will occur.
Da.6 Positioning address/
movement amount
–
–
Setting not required (setting value will be ignored).
Da.7 Arc address
–
–
Setting not required (setting value will be ignored).
Da.8 Command speed
6000.00
mm/min
3000.00
mm/min
Set the speed to be commanded.
Da.9 Dwell time
–
–
Setting not required (setting value will be ignored).
Da.10 M code
10
–
Set this when other sub operation commands are issued in
combination with the No. 1 positioning data. (" Pr.18 M
code ON signal output timing" setting only possible in the
WITH mode.)
Refer to Section 5.3 "List of positioning data" for information on the setting details.
Summary of Contents for D75D4
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 58: ...2 10 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 65: ...3 7 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS ...
Page 139: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 238: ...5 134 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 251: ...6 13 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 254: ...6 16 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 255: ...6 17 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 256: ...6 18 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 259: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 260: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 292: ...7 8 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 294: ...7 10 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 298: ...MEMO ...
Page 462: ...9 140 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 490: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 524: ...11 34 MELSEC Q 11 MANUAL CONTROL Creating the program ...
Page 666: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 675: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 716: ...15 50 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 725: ...Appendix 9 MELSEC Q APPENDICES MEMO ...
Page 878: ...Appendix 162 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 879: ...Appendix 163 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 880: ...Appendix 164 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 893: ...WARRANTY ...
Page 895: ......