6 - 7
MELSEC-Q
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
Device
name
Device
Application
Details when ON
Axis 1 Axis 2 Axis 3 Axis 4
Internal relay
M0
—
OPR request OFF command
Commanding OPR request OFF
M1
OPR request OFF command pulse
OPR request OFF commanded
M2
OPR request OFF command storage OPR request OFF command held
M3
Fast OPR command
Commanding fast OPR
M4
Fast OPR command storage
Fast OPR command held
M5
Positioning start command pulse
Positioning start commanded
M6
Positioning start command storage
Positioning start command held
M7
In-JOG/Inching operation flag
Operating JOG/Inching
M8
Manual pulse generator operation
enable command
Commanding manual pulse generator
operation enable
M9
Manual pulse generator operating flag Operating manual pulse generator
M10
Manual pulse generator operation
disable command
Commanding manual pulse generator
operation disable
M11
Speed change command pulse
Speed change commanded
M12
Speed change command storage
Speed change command held
M13
Override command
Requesting override
M14
Acceleration/deceleration time change
command
Requesting acceleration/deceleration
time change
M16
Step operation command pulse
Step operation commanded
M17
Skip command pulse
Skip commanded
M18
Skip command storage
Skip command held
M19
Teaching command pulse
Teaching commanded
M20
Teaching command storage
Teaching command held
M21
Continuous operation interrupt
command
Requesting continuous operation
interrupt
M22
Restart command
Requesting restart
M23
Restart command storage
Restart command held
M24
Parameter initialization command
pulse
Parameter initialization commanded
M25
Parameter initialization command
storage
Parameter initialization command held
M26
Flash ROM write command pulse
Flash ROM write commanded
M27
Flash ROM write command storage
Flash ROM write command held
M28
—
Error reset
Error reset completed
M29
Stop command pulse
Stop commanded
M30
Target position change command
pulse
Target position change commanded
M31
Target position change command
storage
Target position change command held
M32
ZP.PSTRT1 instruction complete
device
ZP.PSTRT1 instruction completed
M33
ZP.PSTRT1 instruction error failure
device
ZP.PSTRT1 instruction failed
Summary of Contents for D75D4
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 58: ...2 10 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 65: ...3 7 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS ...
Page 139: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 238: ...5 134 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 251: ...6 13 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 254: ...6 16 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 255: ...6 17 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 256: ...6 18 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 259: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 260: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 292: ...7 8 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 294: ...7 10 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 298: ...MEMO ...
Page 462: ...9 140 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 490: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 524: ...11 34 MELSEC Q 11 MANUAL CONTROL Creating the program ...
Page 666: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 675: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 716: ...15 50 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 725: ...Appendix 9 MELSEC Q APPENDICES MEMO ...
Page 878: ...Appendix 162 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 879: ...Appendix 163 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 880: ...Appendix 164 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 893: ...WARRANTY ...
Page 895: ......