5 - 24
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Item
Setting value, setting range
Default
value
Setting value buffer memory
address
Value set with peripheral device
Value set with sequence
program
Axis 1 Axis 2 Axis 3 Axis 4
Pr.7
Bias speed at start
The setting range differs depending on the " Pr.1 Unit setting".
Here, the value within the [Table 1] range is set.
0
6
7
156
157
306
307
456
457
Pr.7 Bias speed at start
Set the bias speed (minimum speed) upon starting. The bias speed has to be
defined to allow the motor to start smoothly especially when a stepping motor is
used. (A stepping motor will not start smoothly if a low rotation speed is
instructed at the beginning.)
The specified "bias speed at start" will be valid during the following operations:
• Positioning operation
• OPR operation
• JOG operation
Note that the bias speed should not exceed " Pr.8 Speed limit value".
Precautions for using a stepping motor
(1) For the system that uses a stepping motor, executing the S-curve
acceleration/deceleration may cause step-out.
Before using the S-curve acceleration/deceleration, confirm that step-out does
not occur.
(2) In the system that uses a stepping motor, the circular interpolation control
cannot be carried out.
Although setting the bias speed at start is required by the characteristics of the
stepping motor, the setting of the bias speed at start is disabled for circular
interpolation control.
Ensure to use a servomotor for both 2 axes when the circular interpolation
control is carried out.
5.2.2 Basic parameters 2
Item
Setting value, setting range
Default
value
Setting value buffer memory
address
Value set with peripheral device
Value set with sequence
program
Axis 1 Axis 2 Axis 3 Axis 4
Pr.8
Speed limit value
The setting range differs depending on the " Pr.1 Unit setting".
Here, the value within the [Table 2] range is set.
200000
10
11
160
161
310
311
460
461
Pr.9
Acceleration time 0
1 to 8388608 (ms)
1 to 8388608 (ms)
1000
12
13
162
163
312
313
462
463
Pr.10
Deceleration time 0
1 to 8388608 (ms)
1 to 8388608 (ms)
1000
14
15
164
165
314
315
464
465
Summary of Contents for D75D4
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 58: ...2 10 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 65: ...3 7 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS ...
Page 139: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 238: ...5 134 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 251: ...6 13 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 254: ...6 16 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 255: ...6 17 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 256: ...6 18 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 259: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 260: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 292: ...7 8 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 294: ...7 10 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 298: ...MEMO ...
Page 462: ...9 140 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 490: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 524: ...11 34 MELSEC Q 11 MANUAL CONTROL Creating the program ...
Page 666: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 675: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 716: ...15 50 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 725: ...Appendix 9 MELSEC Q APPENDICES MEMO ...
Page 878: ...Appendix 162 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 879: ...Appendix 163 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 880: ...Appendix 164 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 893: ...WARRANTY ...
Page 895: ......