5 - 115
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting value
Default
value
Storage buffer
memory address
Axis 1 Axis 2 Axis 3 Axis 4
Set with a decimal.
Setting
value
Positioning data No.
1 to 600
7000 to7004
9001
9002
9003
9004
K
: Positioning data No.
: Block start designation
: Machine OPR
: Fast-OPR
: Current value changing
: Simultaneous starting of multiple axes
0
1500 1600 1700 1800
Set with a decimal.
Setting
value
K
1 to 50
Positioning starting point No.
0
1501 1601 1701 1801
Set with a decimal.
K 1
Error reset request
Setting value
After the axis error reset is completed, "0" is stored by the QD75 automatically.
(Indicates that the axis error reset is completed.)
1: Axis error is reset.
0
1502 1602 1702 1802
Set with a decimal.
K
1
Restart command
Setting value
After restart acceptance is completed, "0" is stored by the QD75 automatically.
(Indicates that the restart acceptance is completed.)
1: Restarts
0
1503 1603 1703 1803
Set with a decimal.
K
1
M code OFF request
Setting value
After the M code ON signal turns OFF, "0" is stored by the QD75 automatically.
(Indicates that the OFF request is completed.)
1: M code ON signal turns OFF
0
1504 1604 1704 1804
Summary of Contents for D75D4
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 58: ...2 10 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 65: ...3 7 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS ...
Page 139: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 238: ...5 134 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 251: ...6 13 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 254: ...6 16 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 255: ...6 17 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 256: ...6 18 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 259: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 260: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 292: ...7 8 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 294: ...7 10 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 298: ...MEMO ...
Page 462: ...9 140 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 490: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 524: ...11 34 MELSEC Q 11 MANUAL CONTROL Creating the program ...
Page 666: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 675: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 716: ...15 50 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 725: ...Appendix 9 MELSEC Q APPENDICES MEMO ...
Page 878: ...Appendix 162 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 879: ...Appendix 163 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 880: ...Appendix 164 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 893: ...WARRANTY ...
Page 895: ......