15 - 47
MELSEC-Q
15 TROUBLESHOOTING
Related buffer memory
address
Set range
(Setting with sequence program)
Remedy
Axis 1 Axis 2 Axis 3 Axis 4
1516 1616 1716 1816
<Speed change request>
1: Speed change is requested
Do not carry out the speed change during deceleration
with a stop command, during stoppage, or during
automatic deceleration with position control.
New speed value
QD75P N/QD75D N:
0 to 4000000 [pulse/s]
0 to 2000000000
[
10
-2
mm/min or others]
QD75P /QD75D :
0 to 1000000 [pulse/s]
0 to 2000000000
[
10
-2
mm/min or others]
Set the new speed value to a range of 0 to "speed limit
value".
1514
1515
1614
1615
1714
1715
1814
1815
Speed limit value
QD75P N/QD75D N:
1 to 4000000 [pulse/s]
1 to 2000000000
[
10
-2
mm/min or others]
QD75P /QD75D :
1 to 1000000 [pulse/s]
1 to 2000000000
[
10
-2
mm/min or others]
10
11
160
161
310
311
460
461
1504 1604 1704 1804
<M code OFF request>
1: M code ON signal is turned OFF
Normalize the ON and OFF timings of the "M code
OFF request". (Refer to Section 12.7.3)
Refer to Section 5.3
"List of positioning data"
<Operation pattern>
00: Positioning complete
01: Continuous positioning control
11: Continuous path control
Set the operation termination to the 50th point.
(Refer to CHAPTER 10)
— — — —
—
Make 1 nest construction for FOR to NEXT.
(Refer to Section 10.3.8)
— — — —
—
Do not turn ON the speed-position switching signal
during acceleration.
(Refer to Section 9.2.16)
— — — —
—
Give a request at the position where there is an
enough remaining distance.
Summary of Contents for D75D4
Page 2: ......
Page 22: ...A 20 MEMO ...
Page 24: ...MEMO ...
Page 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Page 58: ...2 10 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Page 65: ...3 7 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS ...
Page 139: ...5 35 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 238: ...5 134 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Page 251: ...6 13 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 254: ...6 16 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 255: ...6 17 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 256: ...6 18 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 259: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 260: ...6 22 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Page 292: ...7 8 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 294: ...7 10 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS ...
Page 298: ...MEMO ...
Page 462: ...9 140 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Page 490: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Page 524: ...11 34 MELSEC Q 11 MANUAL CONTROL Creating the program ...
Page 666: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Page 675: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 716: ...15 50 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Page 725: ...Appendix 9 MELSEC Q APPENDICES MEMO ...
Page 878: ...Appendix 162 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Page 879: ...Appendix 163 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Page 880: ...Appendix 164 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Page 893: ...WARRANTY ...
Page 895: ......