1-13
1
Setup
Compressed Air Connection
A compressed air connection is required for Model M.
Checking the Compressed Air Pressure
To ensure safe and stable use of the unit, periodically check
the compressed air supply.
Pressure display is located at the position shown in the
diagram.
1
On the first page of the local menu, select
[Z ORIGIN].
• Press
and select.
2
Press
to rotate the router.
• Press
again to stop rotation.
3
Check the compressed air pressure.
• Look at the pressure display to check the compressed
air pressure.
• Adjust the pressure if the pressure display does not
indicate 0.33 MPa.
• After checking, press
.
Drain Bleed
When oil or water collects in the regulator, it bleeds automatically.
You are recommended to spread a towel under the regulator.
• A compressor and air hoses are required to connect the compressed air supply.
• The compressor and air hoses are not available as options. They should be provided by the customer.
Use air hoses with 8 mm connector bore diameter.
• The compressed air must meet the following conditions.
Pressure
: 0.4 MPa
Flowrate
: 50 L/min
Clean, dry air
(Air containing oil or moisture can lead to damage.)
• When the option ZS sensor is mounted, remove
the ZS sensor and check it.
[ LOCA L ]
1 / 5
Z OR I G I N
- - - >
COND I T I ON
- - - >
T ES T CUT
- - - >
Pressure display