4-6
False Detection of Register Marks - Example 3
Register mark separation (TP2 to TP1; TP4 to TP2) does not exceed the register mark length.
J
For single register marks
Guide to Register Mark Separation and Register Mark Size
The chart below shows a guide to the register mark separation (A) and register mark size (B).
The register marks may not be detected correctly if the register mark size (B) is too small with respect to the
register mark separation (A). Create register marks of an appropriate size.
Square register marks
Single register marks
Double register marks
A
200 mm max.
500 mm
1000 mm
1500 mm min.
B
10 mm
15 mm
20 mm
30 mm
Prohibited drawing area
Prohibited drawing area
Separate by at least the
register mark length
Separate by at least the
register mark length
Summary of Contents for CF3-1610
Page 7: ...vi ...
Page 110: ...3 20 ...
Page 124: ...4 14 ...
Page 164: ...6 30 ...
Page 165: ...D201768 14 29062009 ...
Page 166: ...NH FW 3 30 Printed in Japan MIMAKI ENGINEERING CO LTD 2009 ...