Detecting Register Marks
4
4-11
Re
gister Mark Reading
Functions
Register Mark Detection Procedure
1
Mount the workpiece.
2
Press
in local mode.
• The mark search mode is selected.
3
Press the jog keys to accurately align the light pointer to the positions
shown below.
• If SPEED is set to “AUTO” , the speed changes automatically while the jog keys are pressed.
• Press
to move the head to the LR(Lower-Right) position.
4
Press .
• Register mark detection starts.
• If SCALE is set to “before” , when
is pressed, the screen shown at Step 5 appears before
register mark detection starts.
• An error message appears if the register marks cannot be detected. Mount the workpiece again.
5
After the register marks are detected, the
SCALE CORRECT screen appears.
(This example shows 4-point detection.)
• If the data lengths and detected lengths differ, use
to set them.
6
Press
after setting.
• The local mode is selected.
• If SCALE is set to “before”, register mark detection starts.
• Press
to disable the scale correction.
• If [SCALE] is set to OFF, the <SCALE SET> screen is
not displayed.
• If [DETECT] is set to “2pt” , the screen to enter the X
length is not displayed.
• If [DETECT] is set to “1pt” the <SCALE SET> screen
is not displayed.
[ Ma r k S e a r c h ]
S e t L ED P o i n t e r
SPEED
AUTO>
H e a d Mo v e t o LR>
Square
Move near
the center.
Single
Double
Light pointer point
Light pointer point
< SCA L E SE T >
1 - 2 ( X )
4 0 0 . 8 >
1 - 3 ( Y )
1 4 9 . 1 >
Summary of Contents for CF3-1610
Page 7: ...vi ...
Page 110: ...3 20 ...
Page 124: ...4 14 ...
Page 164: ...6 30 ...
Page 165: ...D201768 14 29062009 ...
Page 166: ...NH FW 3 30 Printed in Japan MIMAKI ENGINEERING CO LTD 2009 ...