— 5.2 —
SETTING OF REGISTER MARK DETECT
This function detects a register mark automatically. Use this function to correct the inclination of
the sheet loaded, the position of plotting origin, and the distance between register marks and then
cut the contour of printed image.
If the firmware version is older than 2.50, the register mark is circular
.
How to display the register mark setting on LCD
1
Display the LOCAL menu page 3
Press
PAGE
+
key several times.
2
Select [MODE SET]
3
Display the MODE SET page 6
Press
PAGE
+
key several times.
•
In the case of no sensor model,
page 6 is not displayed.
4
Select [MARK SENSOR]
•
If [expand] is set to ON, can
not select Mark sensor.
Change the setting to OFF. (see
page 4.16.)
[ LOCAL ]
1/ 4
TOOL SELECT
———>
CONDITION
———>
TEST CUT
———>
[ LOCAL ]
1/ 4
INTERFACE
———>
MODE SET
———>
SELF TEST
———>
<MODE SET>
1/ 6
Z SIGN(ZM)
∗
7mm
MULTI-PASS
———>
VACUUM
———>
<MODE SET>
6/ 6
MARK SAENSOR
———>
EXPAND
OFF>
RESERVE
<DETECT SET>
6/ 6
DETECT
OFF>
SIZE
10mm>
STYLE
Square>