— 3.5 —
Register Mark not detected [TOOL Adjust] > [LIGHT POINTER]
If a plotter fails to detect any registration mark properly, the possible cause is an error in the posi-
tional relationship between the mark sensor and the light pointer, or error in the setting of register
mark detect. In this case, adjust the position of the light pointer.
1
Install a water-based ball-point
pen(BK-70) in the ball-point pen
holder. P.2-15
2
Display [Local] menu page 4.
Press the
PAGE
+
key several times.
3
Select [TOOL ADJUST]
4
Display [TOOL ADJUST] menu page
2.
Press the
PAGE
+
key one time.
5
Select [LIGHT POINTER]
6
Select [TEST PATTERN]
Line length of 10mm cross-shape pattern is
plotted.
Light pointer turns on, and move to the cen-
ter of pattern.
[ LOCAL ]
1 / 4
TOOL SELECT
———>
CONDITION
———>
TEST CUT
———>
PAGE
+
[ LOCAL ]
4 / 4
CUT AREA
———>
ALIGN
———>
TOOL ADJUST
———>
[ TOOL ADJUST ]
1 / 2
B CUTTER ADJUST —>
C ROLLER ADJUST
—>
CIRCLE
θ
COR
—>
[ TOOL ADJUST ]
2 / 2
LIGHT POINTEER —>
F1
+
F3
+
<POINTER OFS>
1 / 1
POINTER X + 0.0mm>
POINTER Y + 0.0mm>
TEST PATTERN
—>
F3
+
PAGE
+