— 3.22 —
Error message
Cause
Corrective measure
ERROR 31 NO DATA
ERROR 32
DATA IS TOO LARGE
ERROR 36 MARK DETECT
ERROR 36 MARK DETECT
Stop Data send &
Exec.[DATACLEAR]
- PUSH ANY Key -
ERROR 62 VACUUM
∗∗∗
∗∗∗
∗∗∗
∗∗∗
∗∗∗
OFF-SCALE
∗∗∗
∗∗∗
∗∗∗
∗∗∗
∗∗∗
ERROR 75 ReceCutter
Copy function is executed in the
case where no data is received.
Size of data to be copied exceeds
1 MB.
NO registration mark was
detected.
NO registration mark was
detected.
Overcurrent is fed to the blower.
Data exceeds the effective
cutting area.
(1) Are the cutting conditions suit-
able?
(2) Is the blade worn out?
Transmit data to be copied from
the computer to the device.
Then cut a pattern according to
the data. Then, execute the copy
function. See page 4.4.
Transmit data of which size is
smaller than 1 MB.
Check the sheet for curling
Check to see if the starting point
to detect the registration mark
has been set properly.
Check to see if the black or white
registration mark is printed .
Check to see if there is no dust or
dirt between the registration
marks.
Check to see if there is nmistake
in registration mark settings.
Confirm the status and the
settings described above. If still
no registration mark is detected,
contact your distributor or a sales
office of Mimaki.
Stop data send and clear the data.
(See page 2-42.)
By pressing any keys, return to
the Rocal mode.
Turn off the power to the plotter
and blower. Then, wait for a
while and re-turn on the power to
them.
(1) Interrupt the process (see
page 2.41) and clear the data.
(2) Expand the effective cutting
area, or place the data inside
the effective cutting area.
(1) Set the cutting conditions to
suitable values.
See page P. 2-28.
(2) Replace the blade with a new
one. See page P. 2-14.
Summary of Contents for CF2 Series
Page 48: ...1 32...
Page 120: ...3 24...
Page 138: ...4 18...
Page 176: ...A 12 C OUTPUT SAMPLES Cutting quality 1 Cutting quality 2...
Page 177: ...A 13 ASCII dump list Sample coated...
Page 178: ...A 14 Sample E corrugated Sample B corrugated...
Page 179: ...A 15 Circle cutting R 3 5 10 20 50 100 Parameter dump list R 3 R 5 R 10 R 20 R 50 R 100...
Page 185: ......
Page 186: ...D201402 1 30 16062008 MIMAKI ENGINEERING CO LTD 2008 EM FW 2 50...