— 4.6 —
SETTING THE NUMBER CUT FUNCTION [MODE SET] > [MULTI-PASS]
The same data can be cut as many as five times by changing the pressure values. This allows the
device to efficiently cut a work that cannot be thoroughly cut out by performing cutting once.
However, the number cut function is disabled in unit B.
A period of time required to judge a separating point between pieces of data can also be specified.
The device starts the multi-pass unless the device receives next piece of data within the specified
period of time.
Set values
Period of time required for judgment: Off, 5, 15, 30, 45, 60 Sec
PRESS 1: Off, 500 to 5000 g (in increments of 50 g)
PRESS 2: Off, 500 to 5000 g (in increments of 50 g)
PRESS 3: Off, 500 to 5000 g (in increments of 50 g)
PRESS 4: Off, 500 to 5000 g (in increments of 50 g)
PRESS 5: Off, 500 to 5000 g (in increments of 50 g)
*1: In the RC model, 1000 g to 5000 g.
In the RT model, 300 g to 1500 g.
If the PRESS 1 to PRESS 5 are set to “off,” the device will not perform the multi-pass.
1
Press the
PAGE
+
key several times
until the LCD indicates page 3 of the
LOCAL MENU.
2
Select the [MODE SET].
3
Select the [MULTI-PASS].
4
Establish the [JUDGMENT TIME].
Off, 5, 15, 30, 45, 60 (s)
[ LOCAL ]
1 / 4
TOOL SELECT
———>
CONDITION
———>
TEST CUT
———>
[ LOCAL ]
3 / 4
INTERFACE
———>
MODE SET
———>
SELF TEST
———>
< MODE SET >
1 / 5
Z STROKE
∗
7 mm >
MULTI–PASS
———>
RESERVE
< MULTI–PASS >
1 / 2
JUDGMNT TIME
15 >
PRESS 1
∗
OFF >
PRESS 2
∗
OFF >
PAGE
+
F1
+
F2
+
F2
+
Summary of Contents for CF2 Series
Page 48: ...1 32...
Page 120: ...3 24...
Page 138: ...4 18...
Page 176: ...A 12 C OUTPUT SAMPLES Cutting quality 1 Cutting quality 2...
Page 177: ...A 13 ASCII dump list Sample coated...
Page 178: ...A 14 Sample E corrugated Sample B corrugated...
Page 179: ...A 15 Circle cutting R 3 5 10 20 50 100 Parameter dump list R 3 R 5 R 10 R 20 R 50 R 100...
Page 185: ......
Page 186: ...D201402 1 30 16062008 MIMAKI ENGINEERING CO LTD 2008 EM FW 2 50...