88
SyncServer 600 Series User’s Guide
098-00720-000 Revision B – April, 2016
Chapter 4
Navigation Windows
Holdover occurs when the input references (GNSS, etc.) are not available and
microprocessor is steering the internal oscillator (standard, OCXO, Rubidium).
During holdover the clock accumulates error (drifts away from perfect). By adjusting
the values you can explore the relationship of holdover in days and clock error for
the installed oscillator. When the clock error is reached the server will either unlock
or revert to getting time from other NTP servers. The value obtained with this
estimator is a conservative estimate of the performance of the unit. Actual
performance may vary and will typically be better than this estimate.
Timing - Time Zone Configuration Window
Use this window to select the desired time zone for the SyncServer S6x0. See
below. The time zone is only for the front panel display. NTP time will
continue to be served in UTC.
Figure 4-23. Timing - Time Zone Window
Timing - Serial Output Configuration Window
This window is used to select the format for the serial timing output for the
SyncServer S6x0. See