background image

098-00720-000 Revision B – April, 2016

SyncServer 600 Series User’s Guide

133

Chapter 5  

SyncServer S6x0 CLI Command Set

show system

Use this command to display basic facts about the SyncServer S6x0.

Command Syntax:

show system

Example

SyncServer> show system

Response

Host Name : SyncServer
Serial Num : MSK102
Model Num : S650
Build : 1.0.4
Uname : Linux SyncServer 3.13.0 #1 SMP Tue Nov 17 13:19:51 
PST 2015 armv7l
Uptime : 0 day(s) 0 hour(s) 24 minute(s) 48 second(s)
Load Avg : 0.69 0.42 0.38
Free Mem : 87.83 %
CPU Model : ARMv7 Processor rev 0 (v7l)
CPU Identifier : Altera SOCFPGA
Total Mem : 1007 MB
Oscillator Type : Rubidium
Update Available : Up to date

Summary of Contents for SyncServer S600

Page 1: ...SyncServer S600 SyncServer S650 User s Guide Revision B April 2016 Part Number 098 00720 000 User s Guide updates are available at www microsemi com ftdsupport...

Page 2: ...2016 Microsemi All rights reserved Printed in U S A All product names service marks trademarks and registered trademarks used in this document are the property of their respective owners...

Page 3: ...tion 20 Chapter 1 Overview Overview 24 SyncServer S600 24 SyncServer S650 24 SyncServer S6x0 Key Features 24 Software Options 25 Security Features 25 Physical Description 26 Communications Connections...

Page 4: ...ns 44 Communications Connections 45 SyncServer S6x0 Synchronization and Timing Connections 46 Ethernet Connections 46 Timing I O Module Connections 47 Connecting the GNSS Antenna 49 Connecting Alarm R...

Page 5: ...ation Windows 76 Timing Configuration Windows 86 References Configuration Window 89 Security Configuration Windows 91 Admin Configuration Windows 99 Logs Configuration Windows 107 Option Slot A Config...

Page 6: ...rovisioning Input References 144 Setting GNSS Parameters 144 Provisioning IRIG Inputs on Timing I O Module 145 Provisioning Sine Wave Inputs on Timing I O Module 146 Provisioning NTP Associations 148...

Page 7: ...6x0 Upgrade 170 SyncServer S6x0 Part Numbers 171 System and Accessory Part Numbers 171 GNSS Antenna Kits 173 Returning the SyncServer S6x0 176 Repacking the Unit 176 Equipment Return Procedure 176 Use...

Page 8: ...218 Appendix C Installing GNSS Antennas Antenna Kits Overview 222 Considerations for Antenna Installation 222 Antenna Kits Accessories 224 Antenna Coaxial Cable 226 GNSS Antenna Installation 227 Plann...

Page 9: ...Ground 32 1 18 LEDs for SyncServer S3x0 32 1 19 Web Interface Dashboard 35 2 1 SyncServer S6x0 Location of Product Label 40 2 2 Dimensions for SyncServer S6x0 41 2 3 Rack Mounting the SyncServer S6x0...

Page 10: ...ort Configuration Window 83 4 20 NTP Packet Reflector 84 4 21 Timing Input Control Window 87 4 22 Timing Holdover Window 87 4 23 Timing Time Zone Window 88 4 24 Timing Serial Output Window 89 4 25 Ref...

Page 11: ...ptions Slot A Configuration Window Showing Timing I O Module 108 4 52 Options Slot B Configuration Window Showing Timing I O Module 109 4 53 Help Contacts Window 110 6 1 Example Chrome Browser HTTPS W...

Page 12: ...List of Figures 12 SyncServer 600 Series User s Guide 098 00720 000 Revision B April 2016...

Page 13: ...Port 138 6 2 Adding a New User 140 6 3 Deleting a User 141 6 4 Changing a User s Password 141 6 5 Setting Ethernet Port Parameters 143 6 6 Enable GNSS Port and Set GNSS Parameters 145 6 7 Configure IR...

Page 14: ...ver S6x0 IRIG Output Signal Specifications 205 B 13 SyncServer S6x0 1PPS TOD Output Signal Specifications 205 B 14 SyncServer S6x0 10 MHz Output Signal Specifications 207 B 15 SyncServer S6x0 1PPS Out...

Page 15: ...describes the format layout and purpose of this guide In This Preface Purpose of This Guide Who Should Read This Guide Structure of This Guide Conventions Used in This Guide Warnings Cautions Recomme...

Page 16: ...egories of users Systems Engineers Chapter 1 provides an introduction to the SyncServer S6x0 Cross references in this chapter direct you to detailed system information in other chapters as appropriate...

Page 17: ...tive maintenance and troubleshooting procedures for the product Also contains part number and ordering information and procedures for returning the SyncServer S6x0 Appendix A System Messages Lists the...

Page 18: ...it means SyncServer S6x0 User s Guide The title of a document CRITICAL An operating mode alarm state status or chassis label Select File Open Click the Open option on the File menu Press Enter Press A...

Page 19: ...age to equipment do not disregard ESD cautions All ESD cautions use this symbol ESD cautions are installation operation or maintenance procedures practices conditions or statements that if not strictl...

Page 20: ...Guide The following corrections and additions have been made to the SyncServer S6x0 User s Guide with Rev B Added v1 1 feature information NTP Reflector in NTP Port Configuration Window section and i...

Page 21: ...st St San Jose CA 95134 Toll free in North America 1 888 367 7966 Telephone 408 428 7907 Fax 408 428 7998 email ftd support microsemi com Internet www microsemi com ftdsupport Europe Middle East and A...

Page 22: ...22 SyncServer 600 Series User s Guide 098 00720 000 Revision B April 2016 How to Use This Guide Related Documents and Information...

Page 23: ...Guide 23 Chapter 1 Overview This chapter provides introductory information for the SyncServer S6x0 In This Chapter Overview SyncServer S6x0 Key Features Software Options Security Features Physical De...

Page 24: ...option enables 6 of the BNCs to output any supported signal time codes sine waves programmable rates etc all configurable in real time via the secure web interface This incredibly flexible BNC by BNC...

Page 25: ...t any supported signal time codes sine waves programmable rates and so on all configurable in real time through the secure web interface The 2 input BNCs J1 J2 can support a wide variety of input sign...

Page 26: ...ons and entry buttons Figure 1 2 shows the rear panel connections for the Single AC version of the SyncServer S600 Figure 1 3 shows the rear panel connections for the Dual AC version of the SyncServer...

Page 27: ...User s Guide 27 Chapter 1 Overview Physical Description Figure 1 3 SyncServer S600 Rear Panel Dual AC Version Figure 1 4 SyncServer S650 Front Panel Figure 1 5 SyncServer S650 Rear Panel Single AC Ver...

Page 28: ...100_Full 1000_Full Serial Console Port The serial port connection is made through a DB 9 female connector on the rear panel of the SyncServer S6x0 This port which supports a baud rate of 115 2k 11520...

Page 29: ...put Output Connections Output Connections Serial Data Timing Output Connection The serial data timing port connection is made through a DB 9 female connector on the rear panel of the SyncServer S6x0 a...

Page 30: ...rates The standard configuration offers a broad yet fixed selection of signal I O on its eight BNC connectors see Figure 1 14 J1 is dedicated to time code and rate inputs J2 to sine wave inputs and J...

Page 31: ...power The SyncServer S6x0 is not equipped with a Power switch AC power is controlled by the unplugging the AC power cord Frame ground connections on the SyncServer S6x0 are made on the grounding stud...

Page 32: ...SyncServer S6x0 Single AC Version Power and Ground Figure 1 17 SyncServer S6x0 Dual AC Version Power and Ground Functional Description LEDs The SyncServer S6x0 provides three LEDs on the front panel a...

Page 33: ...limited local control you can configure the SyncServer S6x0 with CLI commands using a terminal or computer with terminal emulation software The connector is located on the front panel The Local port...

Page 34: ...ommand Line Interface Keypad Display Interface The keypad display interface displays the time system status and provides the following functions Configuring and enabling disabling the LAN1 network por...

Page 35: ...Dashboard View See Figure 1 19 for an example of the dashboard status screen that will appear Figure 1 19 Web Interface Dashboard Command Line Interface CLI The Command Line Interface can be used to...

Page 36: ...conditions are deteriorating below specified levels or when issues arise such as loss of power or loss of connectivity These alarms are indicated by LEDs WebGUI status CLI status alarm connector confi...

Page 37: ...or installing the SyncServer S6x0 In This Chapter Getting Started Unpacking the Unit Rack Mounting the SyncServer S6x0 Installation Check List Signal Connections Communications Connections SyncServer...

Page 38: ...e SyncServer S6x0 can be installed in a wide variety of locations Before you begin installation determine the chassis location ensure the appropriate power source is available 120 240 VAC and ensure t...

Page 39: ...ting the equipment in rack Digital multimeter or standard Voltmeter for verifying ground connections to the chassis Unpacking the Unit The SyncServer S6x0 is packaged to protect them from normal shock...

Page 40: ...he model and item number on the equipment The item number can be found on a label affixed to the top of the unit See Figure 2 1 for the location of the label on the SyncServer S6x0 Contact your Micros...

Page 41: ...0 000 Revision B April 2016 SyncServer 600 Series User s Guide 41 Chapter 2 Installing Rack Mounting the SyncServer S6x0 Figure 2 2 Dimensions for SyncServer S6x0 Figure 2 3 Rack Mounting the SyncServ...

Page 42: ...ction is made using the grounding screw which is marked with the universal ground symbol as shown in Figure 2 6 This screw is located on the left side of the rear panel for all models of the SyncServe...

Page 43: ...n 3 Connect the other end of the 1 mm 16 AWG green yellow striped wire to earth ground using local building electrical codes for grounding The suggested method is to crimp the appropriate customer sup...

Page 44: ...power cord into the AC power connector on the SyncServer S6x0 The power receptacles support IEC cable with V locks The V lock will latch the cable to prevent accidental removal of the power cord 2 Pl...

Page 45: ...See Table 2 2 for connector pinouts Serial Console Port The serial port connection is made through a DB 9 female connector on the rear panel of the unit This port which supports a baud rate of 115 2k...

Page 46: ...e standard 100 1000 Base T shielded RJ 45 receptacles which are used for NTP inputs To connect the SyncServer S6x0 to an Ethernet network use an Ethernet RJ 45 cable See Table 2 2 for connector pinout...

Page 47: ...IRIG B AM In 10 MHz In IRIG AM and IRIG DCLS Out 1PPS Out and 10 MHz Out The FlexPort Technology option enables the 6 output BNCs J3 J8 to output any supported signal time codes sine waves programmab...

Page 48: ...8 1 N 1 When connecting to this port use a shielded serial direct connect cable See Figure 2 13 See Table 2 3 for pin outs for this RJ 45 connector Figure 2 13 Data Timing Connection See Table B 13 i...

Page 49: ...ads or parking lots Connecting Alarm Relay The alarm relay output is energized shorted when an alarm activation on this page is configured and with the actual presence off an alarm in alarm state ALAR...

Page 50: ...powers up and begins normal operation the LEDs all turn on After the self test is complete and the firmware is operational the LED states may change to indicate the appropriate state or status Table 2...

Page 51: ...NTP The default value for the date is the software build date This date will be used for the first log entries when booting up the unit The time will change to local time during the boot up process i...

Page 52: ...52 SyncServer 600 Series User s Guide 098 00720 000 Revision B April 2016 Chapter 2 Installing Applying Power to the SyncServer S6x0...

Page 53: ...ices for the keypad display interface ENTER Use with MENU Applies a menu selection or function setting CLR Use with MENU Returns to the previous screen without saving changes Left Right Arrow Buttons...

Page 54: ...e zone setting on TIMING Time Zone page is set to a non UTC local time zone the time display leaves the time scale blank or adds AM PM if the user selects the 12 hour time scale Press the MENU button...

Page 55: ...progression of the NTP clock PLL The field starts with a value of INIT Once a peer has been selected the clock may be stepped in which case the reference ID field changes to STEP Once the PLL is locke...

Page 56: ...ort SM Subnet mask GW Gateway address Hardware Clock Status Screen Hardware Clock and Input Reference status GPS Receiver Status Screen GPS receiver status GNSS Satellites next GPS 1 Max CNo 2 1 numbe...

Page 57: ...ess mode for LAN1 port IPv6 automatically configures LAN1 with a dynamic IPv6 address If Configure is selected the Select LAN1 screen will appear as shown in Figure 3 4 2 On Off Use On to enable the L...

Page 58: ...ress has been entered the LAN 1 port will be reconfigured 2 DHCP Select DHCP addressing type for LAN1 port DHCP automatically configures LAN1 with a dynamic IPv4 address Figure 3 6 Enter LAN1 Static I...

Page 59: ...he Shutdown Factory Default screen on the display as shown in Figure 3 11 Figure 3 11 Shutdown Factory Default Screen See Factory Defaults in Appendix B for default settings 1 Shutdown Halts the SyncS...

Page 60: ...e Lockout function The first time the interface asks for the Current Password enter 95134 No password recover or reset feature is available for the keypad except to reset factory defaults using the Sy...

Page 61: ...st web browsers that a self signed certificate is being used not from a recognized certificate authority Users should accept the warnings and proceed to the login page The internal self signed certifi...

Page 62: ...n Figure 4 2 displays an overall summary of the system Figure 4 2 System Status Status Information Windows The Status Information windows in the dashboard as shown in Figure 4 3 displays status detail...

Page 63: ...status of input references See Table 4 1 Figure 4 4 Timing Window Note The SyncServer 6x0 does not contain a battery backed real time clock Therefore it will always boot up with a default value for th...

Page 64: ...ming source best case an external holdover source or the SyncServer internal reference worst case See Table 4 3 for details of current sources Green if any externally selected reference Amber if inter...

Page 65: ...e that is continuously providing time where continuous is a relative term in general it is an update per second Locked SyncServer outputs are now aligned to a selected active time source Bridging Sync...

Page 66: ...been in holdover for more than a user specified duration and the holdover is based on the SyncServer internal reference In this case the Holdover Sources row will not contain any green items Relocking...

Page 67: ...row This is because the leftmost green item in Timing Sources is the highest priority time source and therefore must be selected For example if it is GNSS it will appear identically as Current Source...

Page 68: ...ow Network Status Information The Network window in the dashboard as shown in Figure 4 6 displays status details and information about the network ports in use Figure 4 6 Network Window NTP Status Inf...

Page 69: ...own in Figure 4 8 displays active alarms Figure 4 8 Alarms Window Slot Modules Status Information The Slot Modules window in the dashboard as shown in Figure 4 9 displays status details about the modu...

Page 70: ...and to view status information See Figure 4 11 The navigation menu will expand and contract depending on the current selection Figure 4 11 Navigation Portion of Dashboard Note The update available fea...

Page 71: ...o manually set the DNS server address for LAN1 There is a separate Apply button for each Ethernet port and the DNS server address configuration The following Ethernet parameters can be configured Spee...

Page 72: ...rs sysName 1 49 characters sysContact 1 49 characters Read Community 1 49 characters Write Community 1 49 characters Add v3 User up to 10 users can be added Name 1 32 characters Authentication Phrase...

Page 73: ...to 10 trap managers can be added Trap Version v2 or v3 User Community 1 32 characters Authentication Phrase v3 only 1 99 characters Privacy Phrase v3 only privacy uses AES128 1 99 characters Authentic...

Page 74: ...74 SyncServer 600 Series User s Guide 098 00720 000 Revision B April 2016 Chapter 4 Navigation Windows Figure 4 14 Network SNMP Traps...

Page 75: ...Chapter 4 Navigation Windows Network Ping Use this window to perform network ping tests Use ping to test network connectivity out the LAN ports as needed The result of the ping will be displayed in t...

Page 76: ...he NTP tab on the dashboard provides access to windows to configure NTP view NTP Daemon Status and Control and to view NTP Associations NTP SysInfo Window Use this window to view NTP Daemon Status and...

Page 77: ...until at least one message has been sent in reply By operating in this mode the host announces its willingness to synchronize and be synchronized by the peer A host operating in client mode a workstat...

Page 78: ...lock it sets the leap indicator to an appropriate value The NTP Leap Change Alarm on the ADMIN Alarms page can be configured to generate an alarm and send notifications each time the leap indicator ch...

Page 79: ...ase where the selected peer is another NTP server the reference ID will display the IP address of the server or a hash unique to the association between the SyncServer and the remote server Reference...

Page 80: ...ndicates that the SyncServer is broadcasting to the remote node marked broadcasting to tilde denotes that the remote node is broadcasting to the SyncServer Local The IP address of the SyncServer netwo...

Page 81: ...ast server Offset ms The time offset between the SyncServer and the remote server in seconds of the last poll The NTP daemon s clock selection algorithm gives preference to lower Offset values The Off...

Page 82: ...l 2016 Chapter 4 Navigation Windows NTP Configuration Window Use this window to configure NTP parameters See Figure 4 18 Figure 4 18 NTP Configuration Window Click the Save button after making changes...

Page 83: ...keys or Autokey The NTP reflector will only support one IP address When using IPv6 there could be multiple IPv6 addresses associated with the Ethernet port The IPv6 address used by the NTP reflector w...

Page 84: ...pports the most common NTP Mode 3 NTP client requests for time The NTP daemon running on the embedded CPU on the other hand is capable of more NTP features and functions The advantage of the SyncServe...

Page 85: ...ad is in excess of what is expected an alarm is sent notifying the user The alarm threshold can be set on the packet monitoring page which is part of the Security section tab When changing the configu...

Page 86: ...the NTP config page if using this mode If the clock state was not free run when entering manual time mode then the unit should be rebooted when leaving manual time mode See Figure 4 21 Note The SyncS...

Page 87: ...ver Configuration Window Use this window to configure a duration in holdover loss of stratum 0 reference until the server either unlocks or attempts to get time from other NTP servers if configured to...

Page 88: ...the server will either unlock or revert to getting time from other NTP servers The value obtained with this estimator is a conservative estimate of the performance of the unit Actual performance may...

Page 89: ...Output Window References Configuration Window The References tab on the dashboard provides access to configure GNSS position and operating mode as well as view Reference Status References Reference St...

Page 90: ...rating mode See Figure 4 26 Figure 4 26 References GNSS Window Note For accurate timing it is important to accurately enter the delay of the antenna and cable If the system has already locked to a ref...

Page 91: ...nd LDAP Security Users Window Use this window to add or delete users and for Password Maintenance See Figure 4 27 Note Only alphanumeric characters hyphen and underline are allowed for the User name a...

Page 92: ...ss control for LAN1 LAN4 whitelist If nothing is configured then the unit will accept data from all devices If any addresses are configured only packets from those devices will be accepted See Figure...

Page 93: ...tem Control Configuration Window Security HTTPS Configuration Window Use this window to configure the web server and certificate info See Figure 4 30 Figure 4 30 Security HTTPS Configuration Window No...

Page 94: ...tion Window Security NTPd Symmetric Keys Configuration Window Use this window to generate upload and download NTP Symmetric Security Keys See Figure 4 32 Figure 4 32 Security NTPd Symmetric Keys Windo...

Page 95: ...ey Client Configuration Window Use this window to configure the NTP Autokey Client and install the IFF Group Key file See Figure 4 34 Figure 4 34 Security NTPd Autokey Client Configuration Window Secu...

Page 96: ...Windows Figure 4 35 Security RADIUS Configuration Window Security TACACS Configuration Window Use this window to enable and configure TACACS authentication Up to 5 TACACS servers can be configured Se...

Page 97: ...on Window Use this window to enable LDAP and configure LDAP settings and servers Up to 5 LDAP servers can be configured See Figure 4 37 Figure 4 37 Security LDAP Configuration Window Note Search base...

Page 98: ...exceeded and identify the impacted port Packets that are handled by the NTP reflector are not counted toward this limit The Service Packets limit sets a threshold to create an alarm when the packet ra...

Page 99: ...and can send and SNMP trap when an upgrade is available Requires that the SyncServer management port have firewall access to the internet Figure 4 39 Admin General Configuration Window Admin Alarm Rel...

Page 100: ...f each alarm and clear individual alarms Use the scroll control on this form to access additional alarms See Figure 4 41 See Table 4 7 for descriptions of Alarm Configuration parameters The SyncServer...

Page 101: ...mechanisms to extinguish that particular alarm indication These include Dashboard Alarms Alarm summary at top of Web GUI Physical alarm connector front panel Alarm LED and Alarm information on front p...

Page 102: ...ether the login banner is displayed before the login interface Users can create a custom banner or use a standard U S government banner See Figure 4 43 Write Log Provides per alarm user control of rep...

Page 103: ...098 00720 000 Revision B April 2016 SyncServer 600 Series User s Guide 103 Chapter 4 Navigation Windows Figure 4 43 Admin Banner Configuration Window...

Page 104: ...o configure the parameters for the Time of Day port and for the console Serial port See Figure 4 44 Figure 4 44 Admin Serial Port Configuration Window Admin Upgrade System Software Window Use this win...

Page 105: ...e file Note For releases after 1 1 if the upgrade process is used to load a previous older version of the software then the unit will reset the configuration to factory default values Note If the all...

Page 106: ...gure 4 46 Admin Options Configuration Window Admin Configuration Backup Restore Reset Use this window to back up restore or reset the SyncServer S6x0 to factory configuration See Figure 4 47 Figure 4...

Page 107: ...tem Log Configuration Window Use this window to set modify or delete IP addresses DNS names of remote systems to which to send log information See Figure 4 48 Figure 4 48 Logs System Log Configuration...

Page 108: ...ges Window Option Slot A Configuration Windows Options Slot A Configuration Window Timing I O Module Use this window to configure the module in Options Slot A The example shown in Figure 4 51 is for t...

Page 109: ...52 Options Slot B Configuration Window Showing Timing I O Module Help Windows Use this window to view information about how to contact Customer Assistance Centers This window can also be used to down...

Page 110: ...110 SyncServer 600 Series User s Guide 098 00720 000 Revision B April 2016 Chapter 4 Navigation Windows Figure 4 53 Help Contacts Window...

Page 111: ...LI commands and telnet CLI commands should be identical Table 5 1 CLI Commands for SyncServer S6x0 Command Similar Web Interface Location set clock Timing Input Control set configuration Admin Configu...

Page 112: ...Serial set nena format Timing Serial show nena format Timing Serial reboot system Admin Services Sys Control set service Admin Services Sys Control show session timeout Admin General set session time...

Page 113: ...er 600 Series User s Guide 111 Chapter 5 SyncServer S6x0 CLI Command Set set clock This command provides an ability to set the time Command Syntax set clock date time date time where date time YYYY MM...

Page 114: ...is prompted with Y to confirm that they really want to do it set configuration factory Returning the configuration to factory defaults also includes Loss of configured user logins Loss of configured n...

Page 115: ...ay each time it receives a T until F9 is cancelled To cancel F9 enter ctrl C on your keyboard The command line disregards all input other than SHIFT T and ctrl C hex 03 The time of day output is only...

Page 116: ...old Time error has exceeded time quality flag 1 s threshold Time error has exceeded time quality flag 2 s threshold Time error has exceeded time quality flag 3 s threshold Time error has exceeded time...

Page 117: ...erver S6x0 responds with the coordinate information in the following format F50 S B N SIGN S DEG d MIN SEC S SIGN S DEG d MIN SEC S ALT UNITS CR LF where F50 Function 50 S ASCII space character one or...

Page 118: ...S MY m S SIGN MZ m CR LF where F ASCII character F 50 function number S ASCII space character B ASCII letter to denote Option Bay number follows N Option Bay Number SyncServer S6x0 only has 1 SIGN Ei...

Page 119: ...haracter F 7 n a n a ASCII character 7 3 n a n a ASCII character 3 SP n a n a ASCII space character one or more S n a n a ASCII character S Status delimiter STATUS Clock Status L Locked U Unlocked The...

Page 120: ...The PLL Synthesizer indicator reports Locked during normal operation while the system clock s PLL is locked to the internal oscillator The PLL indicator reports Unlocked if the SyncServer S6x0 clock s...

Page 121: ...nector supports only frequency inputs 1 5 10MHz This is equivalent to Green indication for Slot A J2 in WebGUI Dashboard Timing Holdover References row Note that Disabling of Slot A J2 will also gener...

Page 122: ...ocked to locked This alarm can only set on a unit that contains an Rb oscillator A Excessive Frequency Adjustment OK X Fault X is indicated when the Excessive Frequency Adjustment alarm is set B Clock...

Page 123: ...April 2016 SyncServer 600 Series User s Guide 121 Chapter 5 SyncServer S6x0 CLI Command Set J For future use OK Always CR n a Carriage return LF n a Line feed Table 5 3 F73 Alarm Indicators Syntax Ala...

Page 124: ...Gnss Status Latitude 12 21 06 39 N Longitude 76 35 05 17 E HGT Val Ellipsoid 712 4 m HDOP 0 970000 PDOP 1 980000 Fix Quality 1 Used Satellites 8 Receiver Status Tracking Operation Mode Survey Antenna...

Page 125: ...perform a Halt Dashboard Security Services Example 1 If using via serial connection to console port SyncServer halt system The system is being HALTED NOW now numerious messages will be received as pr...

Page 126: ...onse 0 2015 11 19 18 49 28 set ip address mode LAN3 ipv4 dhcp 1 2015 11 19 18 49 37 F73 2 2015 11 19 18 49 46 this is not a legal command 3 2015 11 19 18 50 08 show gnss status 4 2015 11 19 18 50 38 s...

Page 127: ...7 Next Boot Image 1 This example tells us that The active image what is currently running in SyncServer S6x0 is 1 0 4 Note that this version is also displayed with the show system command There is a...

Page 128: ...Example SyncServer show ip config Response Eth port config Port Speed IPVersion IPv4Mode IPv6Mode AutoConfig LAN1 AUTO ipv4 DHCP STATIC enable LAN2 AUTO ipv4 STATIC STATIC enable LAN3 AUTO ipv4_ipv6...

Page 129: ...ke effect the specified LAN port must be restarted To set the IPv4 address mask and gateway of the Ethernet interfaces for the specified port set ip ip address lan 1 2 3 4 ipv4 address addrv4_value ne...

Page 130: ...uide 098 00720 000 Revision B April 2016 Chapter 5 SyncServer S6x0 CLI Command Set set nena active Use this command to enable the NENA response mode on this connection Command Syntax set nena active E...

Page 131: ...o display the current NENA format for the CLI connection Command Syntax show nena format Example s650 show nena format Response NENA format 8 set nena format Use this command to set the NENA format fo...

Page 132: ...lent to power up of the SyncServer S6x0 reboot system The behavior of this command is the same as using the Web GUI to perform a Reboot Dashboard Security Services Example 1 If using console port seri...

Page 133: ...e or disable HTTP on the SyncServer S6x0 When disabled the Web interface will not be accessible The only way to re enable HTTP is using this CLI command Disabling HTTP provides a method to effectively...

Page 134: ...is direct to the CONSOLE serial port auto logout will occur upon timeout Command Syntax set session timeout The system will prompt for the timeout value Example To set the session timeout to one hour...

Page 135: ...ow system Example SyncServer show system Response Host Name SyncServer Serial Num MSK102 Model Num S650 Build 1 0 4 Uname Linux SyncServer 3 13 0 1 SMP Tue Nov 17 13 19 51 PST 2015 armv7l Uptime 0 day...

Page 136: ...134 SyncServer 600 Series User s Guide 098 00720 000 Revision B April 2016 Chapter 5 SyncServer S6x0 CLI Command Set...

Page 137: ...is Chapter Establishing a Connection to the SyncServer S6x0 Managing the User Access List Provisioning Ethernet Port Provisioning Input References Setting GNSS Parameters Provisioning IRIG Inputs on T...

Page 138: ...rt has been configured it can be used to access the SyncServer S6x0 web interface Connect the LAN1 port to your network with a CAT5 Ethernet cable Enter the LAN1 port IP address into a web browser Ent...

Page 139: ...ter 6 Provisioning Establishing a Connection to the SyncServer S6x0 Figure 6 1 Example Chrome Browser HTTPS Warning Figure 6 2 Example Chrome Browser HTTPS Warning Advanced Figure 6 3 Example Firefox...

Page 140: ...Console on the rear panel of the SyncServer S6x0 2 Configure the emulation software for 8 data bits 1 stop bit no parity 115 2 kbps baud rate and no flow control Table 6 1 Configuring the LAN1 Port M...

Page 141: ...ess List When you are logged in with the Web GUI you can add edit or delete user names in the user access list The user list can contain up to 15 names in addition to admin Users are required to enter...

Page 142: ...r Answer to password recovery question 6 Enter email address of user for password recovery communication 7 Enter SMTP gateway IPv4 address for SyncServer 8 Click the Apply button CLI n a Front Panel n...

Page 143: ...urity Users 1 Select the user to be deleted with User dropdown box 2 Click the Delete Selected User box 3 Click the Apply button CLI n a Front Panel n a Note Passwords must be at least 8 characters ma...

Page 144: ...decimal notation format xxx xxx xxx xxx to enter the IPv4 address parameter Configuration DHCP or Static The SyncServer S6x0 supports static as well as dynamically allocated IP addresses on the Ether...

Page 145: ...esired port 2 Select the IP address type by clicking on the IPv4 check box 3 Enter the IP address using the dot decimal notation format xxx xxx xxx xxx 4 Enter the Subnet mask using the dot decimal no...

Page 146: ...the GNSS reference is enabled you can set the satellite position parameters either automatically with Survey mode or manually with Position Hold mode The GNSS reference input is enabled by default In...

Page 147: ...button for External Input Sources 2 Click the GNSS check box 3 Click the Apply button 4 Enable GNSS Port References GNSS 1 Enter Elevation Mask value 2 Use drop down box to select Mode of Survey or P...

Page 148: ...eps Notes Web Interface Option Slot A Timing I O Card 1 In the section of the form labeled J1 Input use dropdown box to select the input signal category of interest Timecode Pulse or Off 2 For TimeCod...

Page 149: ...6 8 Configure Sine Wave Inputs on Timing I O Module Method Steps Notes Web Interface Option Slot A Timing I O Card 1 For input J2 use dropdown box to select Sine or Off 2 If sine is selected use the d...

Page 150: ...ibes the method to modify an existing NTP association Table 6 11 provides descriptions of NTP Association configuration parameters The list of Current NTP Associations always includes the local Hardwa...

Page 151: ...e NTP association 3 Select the Port with dropdown box LAN1 LAN2 LAN3 or LAN4 4 Click the Pref checkbox to set this as a prefer association 5 Select the Burst setting with the drowndown box as N A Burs...

Page 152: ...ge the IP address or DNS name if desired of the NTP association 4 Change the Port with dropdown box if desired LAN1 LAN2 LAN3 or LAN4 5 Click the Pref checkbox if desired to select or deselect this as...

Page 153: ...ver the NTP node can be configured in symmetric active mode too When configured the two nodes can synchronize with each other in a variety of failure scenarios such as loss of GPS and Internet connect...

Page 154: ...ut 16s to allow a modem call to complete Once the server is reachable the packet spacing is about two seconds This is designed to speed the initial synchronization acquisition with the server command...

Page 155: ...or certificate file 3 Click the Restart button to make any changes take effect Configure NTP Autokey Server While the NTP daemon restarts its services are temporarily unavailable and it generates the...

Page 156: ...ll IFF Group Key File While the NTP daemon restarts its services are temporarily unavailable and it generates the following alarm events NTP Stratum Change NTP System Peer Change NTP Leap Change Secur...

Page 157: ...ut NMEA 0183 GGA output NMEA 0183 GSV output NMEA 0183 RMC output 3 Click the Apply button Select NMEA output format Timing Serial 1 Select the NENA radio button 2 Click the check box for the desired...

Page 158: ...ports via the secure web interface Provisioning Alarms This section describes the controls used to provision and manage alarms in the SyncServer S6x0 For a list of all alarms see Appendix A System Me...

Page 159: ...ser s Guide 157 Chapter 6 Provisioning Provisioning Alarms The Web GUI allows you to perform the following Provision the severity level Show current alarm settings Show current alarms Display alarm st...

Page 160: ...iggered 6 Use the check box for Send Email to enable disable email notification for the alarm 7 Click the Apply button Clear Alarm 1 Use the check box for Clear Now for the alarm to be cleared 2 Click...

Page 161: ...el n a Table 6 17 Backing Up Provisioning Data Method Steps Notes Web Interface Admin Config Backup Restore Reset 1 Enter a password for Backup and Restore 2 Use the radio button to select Backup 3 Cl...

Page 162: ...ditional security features not available in SNMPv2c In addition to the functions of SNMPv2c SNMPv3 allows user and trapuser levels that are based on authentication and privacy settings The authenticat...

Page 163: ...p add manager command to add a manager IP address Use the set snmp delete manager command to delete a manager IP address The SyncServer S6x0 will support a maximum of 10 manager IP addresses Provision...

Page 164: ...nerate v3 Traps Method Steps Notes Web Interface Network SNMP Traps 1 Enter IP address of SNMP manager 2 Select SNMPv3 3 Enter SNMPv3 user name 4 Enter auth password 5 Select MD5 or SHA for auth 6 Ent...

Page 165: ...32 characters in length The privacy settings are based on the AES encryption standard with a key of up to 32 characters in length All keys are uppercase Table 6 21 Adding Removing v2 Communities Metho...

Page 166: ...SyncServer 600 Series User s Guide 098 00720 000 Revision B April 2016 Chapter 6 Provisioning Provisioning for SNMP Note All character except are accepted for SNMP usernames authentication or privacy...

Page 167: ...r describes maintenance and troubleshooting procedures for the SyncServer S6x0 In This Chapter Preventive Maintenance Safety Considerations ESD Considerations Troubleshooting Repairing the SyncServer...

Page 168: ...guidelines and policies when working on or around live equipment ESD Considerations Maintenance personnel should wear ESD wrist straps when installing or working on all SyncServer S6x0 equipment Plug...

Page 169: ...erver S6x0 incorporates a system reboot function watchdog if any of the system s software become unresponsive If the system s software is unresponsive for 15 minutes then the watchdog timer will repor...

Page 170: ...tatus of ports Network Ethernet or expand the Network tab to see the configuration of each port See Table A 1 in Appendix A System Messages for corrective actions Red Management port LAN1 is not confi...

Page 171: ...n blinking Activity n a Left LED Off No link Right LED Off No link Use the Web GUI to view alarm IDs and descriptions Admin Alarms or expand the Alarm s tab on the Dashboard to see a summary of active...

Page 172: ...ow prior to putting the shelf into service SyncServer S6x0 Upgrade The upgrade process is simple but there will be Loss of Service LOS at reboot The upgrade will take approximately 7 minutes to comple...

Page 173: ...ee Table 7 6 for S600 Build to Order part numbers See Table 7 7 for accessories Table 7 3 Upgrading Firmware Method Steps Notes Web Interface Admin Upgrade 1 Navigate to the location of the authorizat...

Page 174: ...15200 651 SyncServer S650 Timing I O Module Rubidium 090 15200 652 Quickship Options Security Protocols License Option 920 15201 002 Flex Timing Option for Timing I O Module 920 15201 009 Table 7 5 Sy...

Page 175: ...ver and the mounting location of the antenna Any extra cable can be coiled to the side Preconfigured kits that include cable antenna and related mounting accessories are available as shown in Table 7...

Page 176: ...part number 093 15202 001 includes a short SyncServer adapter cable part number 060 00039 000 with BNC m N f connectors All primary antenna cables use N m connectors on either end A single cable must...

Page 177: ...t Total length 200 ft Cable 200 ft antenna kit 093 15202 001 990 15202 200 Kit Total length 225 ft Cable 200 ft lightning arrestor 112 43400 00 3 Cable 25 ft antenna kit 093 15202 001 990 15202 225 25...

Page 178: ...Ensure that the display and connectivity panels are protected when packaged Equipment Return Procedure To return equipment to Microsemi for repair 1 Call Microsemi FTD Services and Support at 888 367...

Page 179: ...manual is updated the updated version will be available for downloading from Microsemi s internet web site Manuals are provided in PDF format for ease of use After downloading you can view the manual...

Page 180: ...ica 1 888 367 7966 Telephone 408 428 7907 Fax 408 428 7998 email ftd support microsemi com Internet www microsemi com ftdsupport Europe Middle East and Africa EMEA Microsemi FTD Services and Support E...

Page 181: ...Messages This section provides information about the system messages that are displayed in response to a provisioning event or to an alarm that occurs when an associated threshold or timer is outside...

Page 182: ...rver S6x0 Command History 22 SyncServer S6x0 Messages events and alarms Severity codes 2 critical Critical critical conditions 3 major Error error conditions 4 minor Warning warning conditions 5 event...

Page 183: ...enerate an SNMP trap Notes Transitory Events represent transitions that have no Set and Clear behavior such as when the first lock occurs after power up see first normal track since powerup alarm Tabl...

Page 184: ...oned out of time frequency bridging state No action required No action required Entered time frequency holdover 6 Minor No Entered time frequency holdover state Transitioned out of holdover state Chec...

Page 185: ...S NTP J1A J2A J2A J2B input selected as frequency reference No action required GNSS Time Qualified 33 Notify No GNSS input time qualified Exit Input Time qualified cleared No action required No action...

Page 186: ...ified cleared No action required No action required J1B Freq Qualified 44 Notify No J1B input freq qualified Exit J1B Input Freq qualified cleared No action required No action required J2A Freq Qualif...

Page 187: ...SS receiver not tracking satellites GNSS receiver not tracking satellites cleared Check Antenna installation Check if Antenna cable is connected properly Installation should conform to the guidelines...

Page 188: ...ction required J1A Input LOS LOSS OF SIGNAL 99 Minor No J1A Input LOS J1A Input LOS cleared Check if cable is securely connected Check signal source is present and configured properly No action requir...

Page 189: ...4 5 6 Check traffic level on network Check for intrusion attempts Check broadcast traffic See Footnote 1 No action required RESERVED 113 Ethernet Port1 link down 115 Minor No LAN1 port link down LAN1...

Page 190: ...connected to Check Auto negotiation No action required RESERVED 119 RESERVED 120 Operational Failure 132 Major No Operational failure 1PPS interrupt GNSS upgrade failure after the 1PPS interrupt Opera...

Page 191: ...ersists after reboot power cycle No action required Temperature out of range 139 Minor No Temperature out of range Temperature out of range cleared Check your operating environment No action required...

Page 192: ...o Timing Quality 1e 5 set Timing Quality 1e 5 cleared n a Timing Quality 1e 4 159 Minor No Timing Quality 1e 4 set Timing Quality 1e 4 cleared n a Timing Quality 1e 3 160 Minor No Timing Quality 1e 3...

Page 193: ...ocol fault cleared Verify IRIG configuration matches source configuration No action required J1B IRIG Input Protocol Fault 171 Minor No J1B IRIG Input protocol fault J1B IRIG Input protocol fault clea...

Page 194: ...s ARP ICMP IGMP Input power not present 175 Minor No No power detected on AC1 AC2 No power detected on AC1 AC2 cleared Connect other power input to AC power if dual power version Verify backup supply...

Page 195: ...Server 600 Series User s Guide 195 Appendix B Specifications and Factory Defaults This appendix provides mechanical and electrical specifications and factory defaults for the SyncServer S6x0 In This A...

Page 196: ...23 in Rack Rack Mounting See Figure 2 2 for drawings with detailed chassis dimensions Width 17 24 in 438 mm Height 1 73 in 44 mm 1 RU Depth 15 00 in 381 mm 15 88 in 403 mm including connectors on rear...

Page 197: ...ications and Factory Defaults Specifications Power SyncServer S6x0 Power Specifications Parameter Description Input Voltage Range 110 220 VAC 50 60 Hz AC Power Standard Oscillator Operating 65 W 542 m...

Page 198: ...0140 RF immunity 10V m 80 1000MHz 80 modulation 900 MHz pulsed at 200 Hz Immunity Conducted ENV50140 RF common mode immunity 0 15 80 MHz 10V 80 modulation EN61000 4 8 Magnetic Field immunity 50Hz 40A...

Page 199: ...Unicast Autokey MD5 RFC1321 SNTP RFC4330 SNMP v2c RFC1441 1452 v3 RFC3411 3418 Custom MIB DHCP RFC2131 DHCPv6 RFC3315 TACACS RFC1492 LDAPv3 RFC4510 4521 RADIUS RFC2865 HTTPS SSL RFC2616 high encryptio...

Page 200: ...al Specifications Parameter Specification Signal Type GNSS L1 Gain Between 15 dB and 30 dB including gain of antenna and loss of cable Frequency GPS 1575 42 MHz center frequency Impedance 50 ohms Coup...

Page 201: ...n Impedance 50 Connector Type BNC Connector Label J1 Signal Level AM Ratio 2 1 to 3 5 1 Amp 1 V to 8 V p p into 50 DCLS 0 8 V for logic 0 2 V for logic 1 Table B 7 SyncServer S6x0 SyncE Input Signal S...

Page 202: ...ut Table B 9 SyncServer S6x0 PPS Input Signal Specifications Parameter Specification Signal Type 0 8 V for logic 0 2 V for logic 1 Impedance 50 Connector Type BNC Connector Label J1 Table B 10 SyncSer...

Page 203: ...ble B 11 SyncServer S6x0 NTPOutput Signal Specifications Parameter Specification Connector Type RJ45 Connector Label Ports 1 2 3 4 Table B 12 SyncServer S6x0 IRIG Output Signal Specifications Paramete...

Page 204: ...sing edge and is sent at a rate of once per second Rise Time 1PPS Pulse 50 ns Pulse Width 50 ms TOD Frame TOD messages use whole 8 bit bytes for transmission with check sum protection Message type and...

Page 205: ...ecifications Parameter Specification Signal type Sine wave Connector type BNC male Connector Label J3 J8 Impedance 50 Signal Level 2 3 Vpp Table B 15 SyncServer S6x0 1PPS Output Signal Specifications...

Page 206: ...N connector on one end and a BNC connector on the other end Other components available in kits or separately include the following Lightning arrestor 112 43400 00 3 Inline Amplifier 112 15202 001 GPS...

Page 207: ...t 21 mm Weight 150 grams Environmental Operating Temperature 40 to 85 C Environmental IP67 CE REACH and RoHS compliant Salt Fog Spray MIL STD 810F Section 509 4 Electrical 1 dB Bandwidth 31 MHz 10 dB...

Page 208: ...cable connections Table B 19 provides mechanical and electrical specifications for the amplifier Table B 18 Lightning Arrestor Specifications Characteristic Specification Type DC Pass Mount Type Bulk...

Page 209: ...32 in 59 mm Operating Temp 40 to 85 C Environmental RoHS REACH and IP67 Electrical Nominal Gain 25 dB 4 0 dB typical Pass Band Ripple 2 dB Impedance 50 Ohms Noise Figure 2 dB typical Bandwidth 1 2 to...

Page 210: ...Group delay 40 ns typical RF connectors Female N type Table B 21 Antenna Cable Specifications Cable Type Loss 1 575 GHz dB per foot DC Resistance per foot Type Center Conductor Flammability RG213 U B...

Page 211: ...ue Value Range Speed Auto Auto Full_100 Full_1000 IPv4 IPv4 uncheck static IPv4 uncheck IPv4 check DHCP IPv4 check Static IP6v IPv6 uncheck autoconfig static IPv6 uncheck IPv6 check Autoconfig uncheck...

Page 212: ...able ASCII 1 49 chars Name v3 User Blank no val printable ASCII 1 49 chars Priv Phrase v3 User Blank no val printable ASCII 1 49 chars Auth Phrase v3 User Blank no val printable ASCII 1 49 chars Min P...

Page 213: ...alue Value Range Role Server Server Peer Address Blank no value IPv4_address IPv6_address dns_ name Port Default LAN1 LAN2 LAN3 LAN4 Prefer uncheck uncheck check Burst N A N A Burst iBurst Both MinPol...

Page 214: ...epends on oscillator type 0 000100 ms to 100 ms Holdover Duration 1 day 0 001 days to 200 00 days Table B 27 Timing Serial Parameters Description Default Value Value Range Output Off Off NMEA NENA Leg...

Page 215: ...ue Range User new user new user admin Delete Selected User checked not checked checked New Username Blank no value Only admin user is retained printable ASCII 1 34 chars New Password Blank no value pr...

Page 216: ...30 Admin General Parameters Description Default Value Value Range Hostname SyncServer Web Session Timeout 10 min 5 10 15 30 60 minutes Check for Software Upgrades checked not checked checked Table B 3...

Page 217: ...y and has not been user cleared or acknowledged Orange condition set at Minor severity and has not been user cleared or acknowledged Red condition set at Major severity and has not been user cleared o...

Page 218: ...ters Serial Data Port Description Default Value Value Range Baud Rate 9600 4800 9600 19 2k 38 4k 57 6k 115 2k Data Bits 8 7 8 Parity none none even odd Stop Bits 1 1 2 Table B 34 Admin Serial Port Con...

Page 219: ...ne component of a complete line of GNSS accessories for your GNSS antenna system provided by Microsemi These accessories are designed to deliver precise GNSS signals over a wide temperature range and...

Page 220: ...NSS L1 antenna mounting bracket and a BNC cable adapter The antennas in line amplifiers and the lightning arrestor have N connectors All antenna kits supplied use a LMR 240 or LMR 400 or equivalent lo...

Page 221: ...a Kit Part Number Total Delay ns Kit Total length 50 ft Cable 50 ft antenna kit 093 15202 001 990 15202 050 107 Kit Total length 75 ft Cable 50 ft lightning arrestor 112 43400 00 3 Cable 25 ft antenna...

Page 222: ...ightning strikes may induce damaging voltages in the antenna system when striking nearby objects attempt to locate the antenna away from lightning rods towers and other structures that attract lightni...

Page 223: ...ds on the length and type of cable used The inline amplifier attaches inline between the antenna and the antenna cable It uses the same power as the antenna and does not require extra wiring The inlin...

Page 224: ...ists the part numbers for the cables and its crimp kit Also see GPS Antenna Coaxial Cable Specifications on page 212 Table C 2 LMR 400 Antenna Coaxial Cable Accessories Part Number Description 121 322...

Page 225: ...e GNSS Antenna Warning The SyncServer S6x0 GNSS interface uses the electrical current it supplies to power a GNSS antenna to determine whether or not the antenna is properly connected and functional I...

Page 226: ...following location and environment influences before installing the GNSS antenna If possible provide the antenna with an unobstructed 360 degree view of the sky from the horizon In general do not all...

Page 227: ...conductor Never connect antenna systems to the same earth ground connector as heating and cooling systems elevator or pump motors or other motors or machinery which can induce noise in the antenna sys...

Page 228: ...et Cable Requirements The total cable length from the GNSS receiver to the antenna must not be shorter than the minimum cable lengths indicated in the GNSS Antenna Kits see Table C 1 Connector Require...

Page 229: ...C Installing GNSS Antennas GNSS Antenna Installation 4 Adhere to local building codes to determine the type and number of fasteners screws bolts etc that may be required Figure C 6 GNSS Antenna Instal...

Page 230: ...arrestor within 30 ft 9 m of the GNSS antenna 2 Connect the ground wire between the lightning arrestor and the proper grounding zone building ground master ground bar or other for the mounting locatio...

Page 231: ...ncServer S6x0 Antenna Installation Completeness Checklist To verify that antenna installation is complete Verify that all power and ground wires are installed correctly and securely fastened Verify th...

Page 232: ...232 SyncServer 600 Series User s Guide 098 00720 000 Revision B April 2016 Appendix C Installing GNSS Antennas GNSS Antenna Installation...

Page 233: ...ware by contacting Microsemi Technical support at the following numbers Worldwide Main Number 1 408 428 7907 USA Canada Latin America including Caribbean Pacific Rim including Asia Australia and New Z...

Page 234: ...ME autoconf PACKAGE VERSION 2 69 RECIPE NAME autoconf LICENSE GPLv2 GPLv3 PACKAGE NAME base files PACKAGE VERSION 3 0 14 RECIPE NAME base files LICENSE GPLv2 PACKAGE NAME base passwd PACKAGE VERSION 3...

Page 235: ...22 RECIPE NAME coreutils LICENSE GPLv3 PACKAGE NAME cracklib PACKAGE VERSION 2 9 1 RECIPE NAME cracklib LICENSE LGPLv2 1 PACKAGE NAME cronie PACKAGE VERSION 1 4 11 RECIPE NAME cronie LICENSE ISC BSD...

Page 236: ...libc extra nss PACKAGE VERSION 2 19 RECIPE NAME eglibc LICENSE GPLv2 LGPLv2 1 PACKAGE NAME elfutils PACKAGE VERSION 0 148 RECIPE NAME elfutils LICENSE GPL 2 Elfutils Exception PACKAGE NAME ethtool PAC...

Page 237: ...RSION 1 0 RECIPE NAME initscripts LICENSE GPLv2 PACKAGE NAME initscripts microsemi PACKAGE VERSION 1 0 RECIPE NAME initscripts microsemi LICENSE BSD PACKAGE NAME ipdynaddrd PACKAGE VERSION 1 1 RECIPE...

Page 238: ...ICENSE GPL 2 0 LGPL 2 1 PACKAGE NAME ldd PACKAGE VERSION 2 19 RECIPE NAME eglibc LICENSE GPLv2 LGPLv2 1 PACKAGE NAME libacl1 PACKAGE VERSION 2 2 52 RECIPE NAME acl LICENSE LGPLv2 1 PACKAGE NAME libapr...

Page 239: ...GPLv2 PACKAGE NAME libcidn1 PACKAGE VERSION 2 19 RECIPE NAME eglibc LICENSE GPLv2 LGPLv2 1 PACKAGE NAME libcom err2 PACKAGE VERSION 1 42 9 RECIPE NAME e2fsprogs LICENSE GPLv2 LGPLv2 BSD MIT PACKAGE NA...

Page 240: ...E NAME libffi LICENSE MIT PACKAGE NAME libform5 PACKAGE VERSION 5 9 RECIPE NAME ncurses LICENSE MIT PACKAGE NAME libfuse2 PACKAGE VERSION 2 8 6 RECIPE NAME fuse LICENSE GPLv2 LGPLv2 PACKAGE NAME libgc...

Page 241: ...ap 2 4 PACKAGE VERSION 2 4 23 RECIPE NAME openldap LICENSE OpenLDAP PACKAGE NAME libltdl PACKAGE VERSION 2 4 2 RECIPE NAME libtool LICENSE GPLv2 LGPLv2 1 PACKAGE NAME liblzma5 PACKAGE VERSION 5 1 3alp...

Page 242: ...KAGE NAME libnetfilter queue1 PACKAGE VERSION 1 0 2 RECIPE NAME libnetfilter queue LICENSE GPLv2 PACKAGE NAME libnfnetlink0 PACKAGE VERSION 1 0 1 RECIPE NAME libnfnetlink LICENSE GPLv2 PACKAGE NAME li...

Page 243: ...NAME libss2 PACKAGE VERSION 1 42 9 RECIPE NAME e2fsprogs LICENSE GPLv2 LGPLv2 BSD MIT PACKAGE NAME libssl1 0 0 PACKAGE VERSION 1 0 1g RECIPE NAME openssl LICENSE openssl PACKAGE NAME libstdc PACKAGE...

Page 244: ...E libtool LICENSE GPLv2 LGPLv2 1 PACKAGE NAME libusb 1 0 0 PACKAGE VERSION 1 0 9 RECIPE NAME libusb1 LICENSE LGPLv2 1 PACKAGE NAME libuuid1 PACKAGE VERSION 2 24 1 RECIPE NAME util linux LICENSE GPLv2...

Page 245: ...otate PACKAGE VERSION 3 8 7 RECIPE NAME logrotate LICENSE GPLv2 PACKAGE NAME ltrace PACKAGE VERSION 0 5 3 RECIPE NAME ltrace LICENSE GPLv2 PACKAGE NAME m4 PACKAGE VERSION 1 4 17 RECIPE NAME m4 LICENSE...

Page 246: ...1 60 25 RECIPE NAME net tools LICENSE GPLv2 PACKAGE NAME netbase PACKAGE VERSION 5 2 RECIPE NAME netbase LICENSE GPLv2 PACKAGE NAME network scripts PACKAGE VERSION 1 0 RECIPE NAME network scripts LICE...

Page 247: ...AME pam_radius PACKAGE VERSION 1 3 17 LICENSE GPL v2 PACKAGE NAME pam_tacplus PACKAGE VERSION 1 3 8 LICENSE GPL v2 PACKAGE NAME parted PACKAGE VERSION 3 1 RECIPE NAME parted LICENSE GPLv3 PACKAGE NAME...

Page 248: ...KAGE VERSION 0 1 RECIPE NAME rwi mod LICENSE GPLv2 PACKAGE NAME sed PACKAGE VERSION 4 2 2 RECIPE NAME sed LICENSE GPLv3 PACKAGE NAME setserial PACKAGE VERSION 2 17 RECIPE NAME setserial LICENSE GPLv2...

Page 249: ...GE VERSION 1 0 RECIPE NAME systemd compat units LICENSE MIT PACKAGE NAME systemd serialgetty PACKAGE VERSION 1 0 RECIPE NAME systemd serialgetty LICENSE GPLv2 PACKAGE NAME tar PACKAGE VERSION 1 27 1 R...

Page 250: ...PACKAGE VERSION 0 7 RECIPE NAME update rc d LICENSE GPLv2 PACKAGE NAME usbutils PACKAGE VERSION 007 RECIPE NAME usbutils LICENSE GPLv2 PACKAGE NAME util linux PACKAGE VERSION 2 24 1 RECIPE NAME util...

Page 251: ...he SyncServer also creates rules to filter IP packets based on the pre assigned role of each Ethernet port The SyncServer assigns different roles to the Ethernet ports The LAN1 port serves the distinc...

Page 252: ...68 SNMPTRAP inbound and outbound UDP packets on port 162 Note that the rules allow inbound packets only outbound packets that are part of the session are allowed to go out of the port Timing Port Rul...