100
SyncServer 600 Series User’s Guide
098-00720-000 Revision B – April, 2016
Chapter 4
Navigation Windows
Figure 4-40. Admin - Alarm Relay Configuration Window
Admin - Alarm Configuration Window
Use this window to configure system alarms. Users can also see the current status
of each alarm and clear individual alarms. Use the scroll control on this form to
access additional alarms. See
for descriptions of Alarm
Configuration parameters.
The SyncServer S6x0 does not have an alarm for a loss-of-power condition as the
alarm relay is not energized when there is no power or there are no alarms. This is
different than legacy products (i.e. XLi) and may need to be taken into account.
Figure 4-41. Admin - Alarm Configuration Window