098-00720-000 Revision B – April, 2016
SyncServer 600 Series User’s Guide
203
Appendix B Specifications and Factory Defaults
Specifications
Output Signals
NTP Output
The timestamps have been compensated for 1000BT. For 100BT, the NTP packets
will have a bias of up to 1 microsecond.
IRIG Output
IRIG outputs are available with the Timing Input/Output Module.
TOD Output
Table B-11. SyncServer S6x0 NTPOutput Signal Specifications
Parameter
Specification
Connector Type
RJ45
Connector Label
Ports
1, 2, 3, 4
Table B-12. SyncServer S6x0 IRIG Output Signal Specifications
Parameter
Specification
Signal Type
IRIG B
Connector Type
BNC
Connector Label
J3, J4, J5, J6, J7, J8
Impedance
50
Signal Level
AM: Ratio 10:3 ± 10%
Amp: 3.5 ± 0.5 Vpp,
DCLS: <0.8 V for logic 0, >2.0 V for logic 1
Table B-13. SyncServer S6x0 1PPS+TOD Output Signal Specifications
Parameter
Specification
Connector Type
9-pin, female D connector
Connector Label
DATA/TIMING
Signal Level
RS-232