098-00720-000 Revision B – April, 2016
SyncServer 600 Series User’s Guide
213
Appendix B Specifications and Factory Defaults
Factory Defaults
NTP
MD5 / SHA (v3)
No check
If v3 check then [ <MD5 check> |
<SHA check> ]
Priv Phrase (v3)
Blank (no value)
[ <printable ASCII> ], 1 - 99 chars
Table B-25. NTP > NTP Configuration Parameters
Description
Default Value
Value Range
Role
Server
Server | Peer
Address
Blank
(no value)
[ <IPv4_address> | <IPv6_address> |
<dns_ name> ]
Port
Default
LAN1 | LAN2 | LAN3 | LAN4
Prefer
uncheck
uncheck | check
Burst
N/A
N/A | Burst | iBurst | Both
MinPoll
Default
Power-of-2 times in seconds range:
default | 16 | 32 | 64 | … | 65536
MinPoll cannot be > MaxPoll
MaxPoll
Default
Power-of-2 times in seconds range:
default | 16 | 32 | 64 | … | 65536
MaxPoll cannot be < MinPoll
Symmeteric
None
None | Auto | 1 | 2 | … | 17 | 18 | 19 | 20
Table B-24. Network > SNMP Traps Parameters (Continued)
Description
Default Value
Value Range