![Microsemi SyncServer S600 User Manual Download Page 157](http://html1.mh-extra.com/html/microsemi/syncserver-s600/syncserver-s600_user-manual_1788481157.webp)
098-00720-000 Revision B – April, 2016
SyncServer 600 Series User’s Guide
155
Chapter 6 Provisioning
Provisioning Outputs
Provisioning Outputs
Provisioning the Serial Timing Output
The serial timing outputs (on port labeled "DATA/TIMING") can be configured for
NMEA, NENA, or serial legacy output format.
Table 6-14. Configure Serial Timing Output
Method
Steps
Notes
Web Interface
Timing > Serial
1. Select the NMEA radio button.
2. Click the check box or
combination of check boxes for
the desired type(s) of NMEA
output format:
- NMEA - 0183 ZDA Output
- NMEA - 0183 GGA output
- NMEA - 0183 GSV output
- NMEA - 0183 RMC output
3. Click the
Apply
button.
Select NMEA output
format.
Timing > Serial
1. Select the NENA radio button.
2. Click the check box for the desired
type of NENA output format.
- DDD HH:MM:SS DTZ=XX
- WWW DDMMMYY HH:MM:SS
- YYYY DDD HH:MM:SS DZZ
3. Click the
Apply
button.
Select NENA output
format.
NENA ASCII time code is
sent in
broadcast mode
,
in which the code is sent
once per second at the
beginning of the second
(Data/timing serial port).
Timing > Serial
1. Select the Legacy Serial Output
radio button.
2. Click the
Apply
button.
Timing > Serial
1. Click the
Off
radio button at the
top of the dialog box.
2. Click the
Apply
button.
Turn Serial Timing Output
off.
CLI
n/a
n/a
Front Panel