Installation and Initial Operation
thicknessCONTROL MTS 8201.LLT / 4350006.71
4.8
Position of Measured Object
The measuring ranges of the sensors employed are decisive when positioning the target in the gap. The target must
be within both sensor measuring ranges for a correct thickness measurement. Use the passline
Guide the target through the measuring system at the correct installation height. Use the red marking on the
. Refer to the mechanic documentation for the exact dimensions
A
A
660
0
660
1140
1505
1250
(1320)
899
929.5
990
1320
1430
1515
206.5
0
671.5
(passline)
900
1166
1281.5
1746.5
1811.5
709
(measurement range end)
951
(measurement range start)
891
electrical and
pneumatical connection
Target
1
Fig. 30 Parameters for positioning the measured object
1
Target characteristics
Width:
min. 609.6 mm
max. 1320.8 mm
Thickness:
min. 0.305 mm
max. 7.112 mm
Take appropriate measures, e.g. guide rollers, to ensure that the target does not hit the measuring system.
Fig. 31 Red marking on the measuring system
Summary of Contents for 4350006.71
Page 12: ...Page 12 Laser Safety thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Page 62: ...Page 62 Instruction Manual Software thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Page 64: ...Page 64 Pneumatic Plan thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Page 70: ...Page 70 Declaration of Incorporation thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Page 95: ...Operating Instructions scanCONTROL 29xx ...
Page 100: ......
Page 135: ...Page 41 Operation of the Sensor with a PC scanCONTROL 29xx Fig 24 Predefined measuring fields ...
Page 193: ......
Page 194: ......
Page 229: ......