Page 61
Installation and Assembly
English
capaNCDT 6100
4.5
Power Supply and Signal Output
The power supply and signal output are connected by the 8-pin built-in connector (DlN 45326). Pin assignment,
see
. The controller contains a 8-pin cable socket for the user-side assembly of your own connecting cable.
PIN
Assignment
1
6
7
3
5
2
8
4
i
Requirements
ofpower and
output cables to
satisfy the EMC
regulations.
1
0 Volt (24 V operation)
2
+15 Volt (Option)
3
Output A displacement signal/voltage
4
-15 V (Option)
5
0 Volt (±15 V operation)
6
+24 Volt (24 V operation)
Solder pin side
cable socket
7
0 Volt (analog output)
8
Output B signal option (e.g. current)
Fig. 6 Pin assignment
In addition the following applies:
Use a double screened cable!
- Outer screening mesh surrounds all cable wires.
- Inner screening mesh surrounds signal wires PIN 3, 7, 8.
- Inner screening mesh at pin 7.
- Total screen via connector housing to housing ground
- Recommended conductor cross-section 0.14 mm
2
(AWG 26)
The EMC regulations, see Chap.
, are only satisfied under these basic conditions.
PC3/8 is a 3 m (9.84 ft) long, pre-assembled 8-wire power and output cable. It is supplied as an accessory.
Summary of Contents for 4350006.71
Page 12: ...Page 12 Laser Safety thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Page 62: ...Page 62 Instruction Manual Software thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Page 64: ...Page 64 Pneumatic Plan thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Page 70: ...Page 70 Declaration of Incorporation thicknessCONTROL MTS 8201 LLT 4350006 71 ...
Page 95: ...Operating Instructions scanCONTROL 29xx ...
Page 100: ......
Page 135: ...Page 41 Operation of the Sensor with a PC scanCONTROL 29xx Fig 24 Predefined measuring fields ...
Page 193: ......
Page 194: ......
Page 229: ......