MI 3309 DeltaGT
Main menu and test modes
22
4 Main menu and test modes
4.1 Instrument Main menu
From the Main menu of the instrument there are five
instrument operation modes, Help
menu and Setup menu can be selected:
Figure 4.1: Instrument Main menu
Keys:
/
TAB
Select one of the following menu items:
<
VDE ORGANIZER
> pre-programmed test sequences according to the
VDE 0701-0702 norm, see
chapter 6.1 VDE organizer setup menu
;
<
SINGLE TEST
> individual tests, see
chapter 5 Single test
;
<
CUSTOM AUTOTEST
> user defined pre-programmed sequences, see
chapter 6.2 Custom autotest
;
<
SIMPLE TEST
> simple pre-programmed sequences, see
chapter 6.3
Simple test
<
CODE AUTOTEST
> code-based test sequences, suitable for working with
barcodes and RFID tags, see
chapter 6.4 Code Autotest
;
<
HELP
> help screens;
<
SETUP
> menu for setup of the instrument, see
chapter 4.7 Setup menu
;
TEST
Confirms selection.
4.2 VDE Organizer menu
This menu offers creation and performing of VDE compatible test sequences. The
sequence setup and its parameters are the same as suggested in the VDE 0701-0702
standard. After an autotest sequence has been created in the VDE organizer, it can be run
as an autotest or stored in the Custom Autotest menu.
Figure 4.2: VDE organizer menu
See chapter
6.1 VDE organizer setup menu
for more information.