MI 3309 DeltaGT
Autotest sequences
59
Reading appliance ID number with barcode scanner or RFID reader/writer
When the instrument is in the Save results menu, appliance ID can be scanned from a
barcode label with the barcode reader or can be read from RFID tag with the RFID
reader/writer. A successful receive of the barcode or RFID tag is confirmed by two short
confirmation beeps.
6.5 Carrying out autotest sequences (Code, Simple and
Custom)
General meaning of keys during Code, Simple and Custom autotest sequences:
TAB,
/
Set option. Set limit value in selected (highlighted) item.
ESC
Cancels autotest sequence and returns to the autotest menu (Code,
Simple or Custom) without changes.
TEST
Starts / repeats selected measurement or proceeds to the next step.
Notes
If any of the inspections are marked as failed or if any test fails the test sequence is
stopped and the instrument automatically goes to the
Result
menu.
If a test parameter (limit, duration, output voltage) is changed the setup is valid only
for the particular test.
If the test limit, output voltage or test duration is changed in Code autotest
sequence the autotest code will not be stored (as the settings do not correspond
with the code anymore).
6.5.1 Visual inspection
Measurement is described in chapter
5.2.1 Visual inspection
.
Figure 6.26: Visual test menu
Options in Visual inspection:
PASS / FAIL
To be applied manually.
6.5.2 Earth continuity resistance measurement
The test is offered if it is applicable according to the autotest setting. The Earth continuity
starting screen is displayed first. Measurement and options in Earth continuity starting
screen are described in chapter
5.2.2 Earth continuity resistance
.
Figure 6.27: Earth continuity starting screen
After the measurement is carried out the Earth continuity result screen is displayed.