SECTION 4
MAINTENANCE
79
C
A
B
E
D
Cleaning Ink Tank Contacts & Prism
After reinstalling or replacing Ink Tanks the Ink Level indicators on the Touchscreen may not refresh.
This may be due to a dirty Ink Tank Level Prism and/or QA Chip contacts on that Ink Tank(s).
Clean contacts and prism as follows:
1.
Remove Ink Tank(s).
Open Ink
Tank Door. Release Ink Tank
Latch(s)
[A]
. Remove Ink Tank(s)
[B]
that did not refresh.
Tip:
This would be a good time to
inspect the Waste Ink Tray
[C]
.
Replace if full or near full (white pad
all or mostly black with ink).
Make sure that it is securly installed,
tabs locked into frame at both sides.
2.
Clean QA Chip contacts
[D]
with a clean, dry, lint-free
cloth. Contacts may also be lightly cleaned with a pencil
eraser to remove oxidation.
3.
Clean Ink Level Prism
[E]
with a cloth that has been
dampened with distilled water.
CAUTION
: Do NOT get QA Chip contacts wet. If you
accidently get them wet, make sure they are dry before
re-installing Ink Tank.
4.
Reinstall Ink Tank(s) (
labels up
), close and Lock Ink
Tank Latch(s)
[A]
. Make sure the bottom of the Latch
is locked at both sides.
5.
Close Ink Tank Door.
WARNING!
Ink in Ink Tanks may be harmful if swallowed. Keep new and used Ink Tanks
out of reach of children. Discard empty Ink Tanks immediately.
Summary of Contents for Quadient Rena MACH 6