Revision 1.7.2
Page 13
4.2.8 Elec. Distribution
The DSM410 supports control of the DCR100, Carling OctoPlex AC and DC Boxes, and other
electrical distribution devices that utilize NMEA Command of the 127501 Binary Switch Status
message for controlling loads.
Switch/Breaker
– controls the ON/OFF state of a switch or circuit breaker
Breaker Current
– displays current through a switch or circuit breaker
Hardware OFF Counter
– displays the value of a hardware counter in Maretron’s DCR100,
SIM100 and RIM100 that count the number of the times the indicator has transitioned to the
OFF state. This counter may be reset with the control mode of the display
– see Section
5.2.7.14 for details)
Hardware ON Counter
– displays the value of a hardware counter in Maretron’s DCR100,
SIM100 and RIM100 that count the number of the times the indicator has transitioned to the
ON state. This counter may be reset with the control mode of the display
– see Section
5.2.7.14 for details)
Hardware ERROR Counter
– displays the value of a hardware counter in Maretron’s DCR100,
SIM100 and RIM100 that count the number of the times the indicator has transitioned to the
ERROR state. This counter may be reset with the control mode of the display
– see Section
5.2.7.14 for details)
Hardware OFF Timer
– displays the value of a hardware timer in Maretron’s DCR100, SIM100
and RIM100 that accumulates the elapsed time that the indicator has spent in the OFF state.
This timer may be reset with the control mode of the display
– see Section 5.2.7.14 for details)
Hardware ON Timer
– displays the value of a hardware timer in Maretron’s DCR100, SIM100 and
RIM100 that accumulates the elapsed time that the indicator has spent in the ON state. This
timer may be reset with the control mode of the display
– see Section 5.2.7.14 for details)
Hardware ERROR Timer
– displays the value of a hardware timer in Maretron’s DCR100,
SIM100 and RIM100 that accumulates the elapsed time that the indicator has spent in the
ERROR state. This timer may be reset with the control mode of the display
– see Section
5.2.7.14 for details)
4.2.9 Engine
The DSM410 supports the display of information for up to 64 engines.
Boost Pressure
– displays the boost pressure of a supercharger or turbocharger
Hours
– displays the number of hours of operation reported by the engine
Coolant Pressure
– displays the engine’s coolant pressure
Coolant Temp.
– displays the engine’s coolant temperature
Exhaust Gas Temp
.
– displays the temperature of the engine’s exhaust gas
Fuel Pressure
– displays the pressure of the fuel for the engine
Fuel Rate
– displays the rate of fuel consumption for the engine
Oil Pressure
– displays the engine’s oil pressure
Oil Temp.
– displays the engine’s oil temperature
Tachometer
– displays the rotational speed of the engine
Tilt/Trim
– displays the tilt or trim of the drive
Voltage
– displays the electrical power supply voltage measured at the engine
Fuel Economy
(Dis./Vol.)
– displays the current fuel economy for the engine
Fuel Consumption
(Vol./Dis.)
– displays the current fuel consumption for the engine
Percent Load
– displays the current load on the engine as a percentage of rated load
Percent Torque
– displays the current torque from the engine as a percentage of rated torque