DSM410
User’s Manual
Page 246
Revision 1.7.2
Figure 289
– Outside Alert Parameters
8.3.7.7.2 Trigger Configuration
– Outside Radius Alert
Figure 290
– Trigger Configuration – Outside Radius Alert
Re-trigger Period
– When you accept an alert, it will change to the “Accepted” state, and
annunciators that are sounding for that alert will stop sounding. If the condition which caused
the alert remains
true after the amount of time in this field, the alert will return to the “Active”
state, and annunciators will begin sounding again for that alert. If a value of 0:00 is entered,
then the alert will never re-trigger.
Alert Set Point
– If the distance between the current GPS position and the reference position
rises above the value in this field, the alert will become active.
Alert Set Delay
– The distance between the current GPS position and the reference position must
rise above the Outside Radius Alert Set value for longer than the time in this field in order for
an alert to become active.
Alert Clear Point
– If the alert is active and the distance between the current GPS position and
the reference position falls below the value in this field, the alert will become inactive.