Revision 1.7.2
Page 151
The second step in the custom rudder angle sender calibration process is to turn the wheel so that
the rudder is centered as much as possible. Next, press Enter to accept the value and store it within
the RAA100. Figure 153 shows a screenshot of the center rudder calibration screen. You may also
press the Abort Key (
) to end the calibration process.
Figure 153
– RAA100 Center Rudder Angle Calibration
The third step in the custom rudder angle sender calibration process is to turn the wheel hard over to
port, and to measure the angle or the rudder (angle from center) with a protractor or other instrument.
Use the Increase and Decrease keys until the highlighted rudder angle value is at the measured
value, and then press Enter to accept the value and store it within the RAA100. Figure 152 shows a
screenshot of the starboard rudder calibration screen. You may also press the Abort Key (
) to end
the calibration process.
Figure 154
–
RAA100 Port Rudder Angle Calibration
Once you have accepted the port rudder angle value, a confirmation screen appears indicating that
the rudder angle calibration has been successfully completed. Figure 155 below shows a screenshot
of this confirmation screen.