Revision 1.7.2
Page 189
keys to move the highlighted cursor over the “Tank Capacity:” menu item. Then, press the
Enter
key
to move the highlight over the numerical tank capacity value. Use the
Increase
and
Decrease
keys to
change the value to the desired tank capacity value, and finally, press the
Accept
key to confirm your
selection.
Figure 210
– Configuring the Tank Capacity
After you have pressed the
Accept
key, a confirmation screen will appear that warns you that the
fluid remaining measurement will change as a result of this change. Press the
Accept
key to accept
the change and store the new tank capacity value within the TLM100, or Press the
Cancel
Key to
cancel the change and leave the old tank capacity programmed into the TLM100.
Figure 211
– Tank Capacity Change Confirmation Screen
6.26.4
Tank Levels Calibration
In order for the TLM100 to indicate an accurate tank level, it must know the geometry of the tank.
There are two methods of calibrating the tank level sender:
Custom Calibration
– use for non-rectangular tanks (also, most accurate in any case, but
requires more effort)