Revision 1.7.2
Page 185
Figure 204
– Configuring the Operating Mode
6.25.8
Gauge Resistance, + to Sender
If the desired operating mode is “NMEA 2000 & Analog Gauge”, the two gauge resistances must be
programmed (please refer to the
TLA100 User’s Manual
for details on how to perform these
measurements). A screenshot of the + to sender gauge resistance configuration is shown in Figure
205 below. To program the + to sender gauge resistance, use the Scroll Up (
) or Scroll Down (
) keys to move the highlighted cursor over the “Gauge Resistance, + to Sender:” menu item.
Then, press the Enter key (
) to move the highlight over the numerical resistance value. Use the
“Increase” and “Decrease” keys to change the value to the measured resistance value, and finally,
press the Enter key (
) to confirm your selection and store the value within the TLA100.
Figure 205
– Configuring the + to Sender Gauge Resistance
6.25.9
Gauge Resistance, - to Sender
If the desired operating mode is “NMEA 2000 & Analog Gauge”, the two gauge resistances must be
programmed (please refer to the
TLA100 User’s Manual
for details on how to perform these
measurements). A screenshot of the - to sender gauge resistance configuration is shown in Figure
206 below.