IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-25
Swift-Lift™
Swift-Lift provides additional productivity by allowing a hoist to quickly move into position by
increasing speeds under light or no load conditions. Swift-Lift will enable the motor to over-speed
by calculating the maximum safe speed and automatically accelerating to this speed. However, the
maximum speed cannot exceed the lesser of the Swift-Lift Forward Speed (C06.02) or Swift-Lift
Reverse Speed (C06.03) and the Max Output Frequency (E01.04).
NOTE:
Swift-Lift is disabled when in traverse applications.
The maximum frequency (E01.04)
C06.02 and C06.03.
There are two methods that may be utilized to enable Swift-Lift:
1) Automatic: Swift-Lift can be enabled to automatically occur whenever the load is less than the
maximum percentage of motor current (C06.04 or C06.05) and the output frequency is greater than
the Swift Lift Enabling Speed (C06.06).
2) Manual: Swift-Lift may be enabled manually through the Multi-Functional Digital Inputs by
setting H01.01 ~ H01.07 = 13.
Parameter
Code
Name
Function
Range
Initial
Value
Access
Level
C06.01
Swift-Lift
Determines whether Swift-
Lift is enabled.
00–02
00
Basic/Adv
00 Disabled
01 Enabled Automatic
02 Enabled by MFI = 13
C06.02
Swift-Lift Forward Speed
Maximum Output
Frequency during Swift-
Lift—FORWARD.
0.0–150.0 Hz
60.0
Basic/Adv
C06.03
Swift-Lift Reverse Speed
Maximum Output
Frequency during Swift-
Lift—REVERSE.
0.0–150.0 Hz
60.0
Basic/Adv
C06.04
Swift-Lift Forward Torque
Maximum output current
below which Swift-Lift—
FORWARD is enabled.
000–100%
50
Basic/Adv
C06.05
Swift-Lift Reverse Torque
Maximum output current
below which Swift-Lift
REVERSE is enabled.
000–100%
30
Basic/Adv
C06.06
Swift-Lift Enabling Spd
Threshold frequency at
which Swift-Lift is
enabled.
0.0–150.0 Hz
59.0
Basic/Adv
C06.07
Swift-Lift Delay Time
Delay time at enabling
speed prior to torque-
compare function.
0.0–25.5 sec
2.0
Basic/Adv
C06.08*
Swift Lift Acceleration
Gain
Speed feedback
acceleration multiplier
0.1–9.9
1.0
Adv
* Only available when A01.02 = 00 (V/f)
WA R N I N G
Motors and drive machinery must be capable of operating above motor base speed. Consult
the motor/gearbox/hoist manufacturer before enabling Swift-Lift function. Failure to observe
this warning may result in damage to equipment and possible injury or death to personnel.
Summary of Contents for 2001-G+M
Page 2: ......
Page 9: ...C h a p t e r 1 Introduction...
Page 10: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 2 This page intentionally left blank...
Page 16: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 8 This page intentionally left blank...
Page 17: ...C h a p t e r 2 Installation...
Page 18: ...IMPULSE G Mini Advanced Instruction Manual March 2014 2 2 This page intentionally left blank...
Page 25: ...C h a p t e r 3 Wiring...
Page 26: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 2 This page intentionally left blank...
Page 38: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 14 This page intentionally left blank...
Page 39: ...C h a p t e r 4 Getting Started...
Page 40: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 2 This page intentionally left blank...
Page 60: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 22 This page intentionally left blank...
Page 61: ...C h a p t e r 5 Programming Features...
Page 62: ...IMPULSE G Mini Advanced Instruction Manual March 2014 5 2 This page intentionally left blank...
Page 153: ...Troubleshooting IMPULSE G Mini C h a p t e r 6...
Page 154: ...IMPULSE G Mini Advanced Instruction Manual March 2014 6 2 This page intentionally left blank...
Page 165: ...IMPULSE G Mini Advanced Parameter Listing A p p e n d i x A...
Page 166: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 2 This page intentionally left blank...
Page 190: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 26 This page intentionally left blank...