Reference Detection
The IMPULSE•G+ Mini utilizes three different functions for detecting output frequency:
•
When frequency agree is enabled using the multi-function contact outputs (H02.XX =
“002” or “013”), the contact closes whenever the output frequency “agrees” with the
frequency reference, plus or minus the speed agree detection width.
•
When desired frequency agree is enabled using the multi-function contact outputs
(H02.XX = “003” or “014”), the contact closes whenever the output frequency
“agrees” with the speed agree detection level, plus or minus the speed agree
detection width.
•
When frequency detection is enabled using the multi-function contact outputs
(H02.XX = “004,” “005,” “015,” “016,”“104,” “105,” “115,” or “116”), the
contact opens or closes whenever the output frequency is less than or more than the
speed agree detection level, depending on which detection is selected.
Parameter
Code
Name
Function
Range
Initial
Value
Access
Level
L04.01
Speed Agree Level
Speed Agree Level ±
0.0–150.0 Hz
0.0
Basic/Adv
Sets the detection level for the desired frequency agree 1 and frequency detection 1 and 2 functions.
The set detection level is effective during both FWD and REV operation.
Parameter
Code
Name
Function
Range
Initial
Value
Access
Level
L04.02
Speed Agree Width
Speed Agree Width ±
0.0–20.0 Hz
2.0
Adv
Sets the detection width for frequency and desired frequency agree 1 and frequency detection 1 and 2
functions.
Parameter
Code
Name
Function
Range
Initial
Value
Access
Level
L04.03
Speed Agree Lvl ±
Speed Agree Level ±
-150.0–150.0 Hz 0.0
Adv
Sets the detection level for the desired frequency agree 2 and frequency detection 3 and 4 functions.
The set detection level is effective during either FWD or REV operation, depending on the set
detection level (positive value for FWD operation, negative value for REV operation).
Parameter
Code
Name
Function
Range
Initial
Value
Access
Level
L04.04
Speed Agree Width ±
Speed Agree Width ±
0.0–20.0 Hz
2.0
Adv
Sets the detection width for frequency and desired frequency agree 2 and frequency detection 3 and 4
functions.
Summary of Contents for 2001-G+M
Page 2: ......
Page 9: ...C h a p t e r 1 Introduction...
Page 10: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 2 This page intentionally left blank...
Page 16: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 8 This page intentionally left blank...
Page 17: ...C h a p t e r 2 Installation...
Page 18: ...IMPULSE G Mini Advanced Instruction Manual March 2014 2 2 This page intentionally left blank...
Page 25: ...C h a p t e r 3 Wiring...
Page 26: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 2 This page intentionally left blank...
Page 38: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 14 This page intentionally left blank...
Page 39: ...C h a p t e r 4 Getting Started...
Page 40: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 2 This page intentionally left blank...
Page 60: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 22 This page intentionally left blank...
Page 61: ...C h a p t e r 5 Programming Features...
Page 62: ...IMPULSE G Mini Advanced Instruction Manual March 2014 5 2 This page intentionally left blank...
Page 153: ...Troubleshooting IMPULSE G Mini C h a p t e r 6...
Page 154: ...IMPULSE G Mini Advanced Instruction Manual March 2014 6 2 This page intentionally left blank...
Page 165: ...IMPULSE G Mini Advanced Parameter Listing A p p e n d i x A...
Page 166: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 2 This page intentionally left blank...
Page 190: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 26 This page intentionally left blank...