![background image](http://html1.mh-extra.com/html/magnetek/2001-g-m/2001-g-m_instruction-manual_3598661132.webp)
IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-72
Torque Detection
The overtorque detection circuit activates when the motor load causes the motor current to exceed
the overtorque detection level (L06.02). When an overtorque condition is detected, alarm signals
will be shown on the keypad as well, and can be sent to a multi-function output. To output an
overtorque detection signal, select torque detection 1 at either of the multi-function contact outputs
(H02.xx = “00B,” “017,” “10B,” or “117”).
NOTE:
•
To detect overtorque during acceleration or deceleration, set to “02” or “04” / “06” or “08”.
•
To continue operation after overtorque detection, set to “01” or “02” / “05” or “06”. During
detection, the digital operator displays an “OT1/UT1” alarm (blinking).
•
To stop the inverter after an overtorque detection fault, set to “03” or “04” / “07” or “08”.
During detection, the digital operator displays an “OT1/UT1” fault.
Parameter
Code
Name
Function
Range
Initial
Value
Access
Level
L06.01
Torque Detect 1 Select
Activates overtorque/
undertorque detection and
selects whether detection
generates an alarm or a fault
00–08
00
Basic/Adv
00 Disable
Basic
01 Overtorque At Speed
Agree (Alarm)
Basic
02 Overtorque
At
Run
(Alarm)
Basic
03 Overtorque At Speed
Agree (Fault)
Basic
04 Overtorque At Run
(Fault)
Basic
05 UT At Speed Agree
(Alarm)
Adv
06 UT At Run (Alarm)
Adv
07 UT At Speed Agree
(Fault)
Adv
08 UT At Run (Fault)
Adv
Table 5-10: Torque Detection 1 Selection Definition
Setting
Description
00
Torque detection is disabled (
factory default
).
01
Overtorque detection is enabled whenever at the speed agree level (when inverter is not accelerating or
decelerating). Continue running after detection (OT1 alarm).
02
Overtorque detection is enabled always. Continue running after detection (OT1 alarm).
03
Overtorque detection is enabled whenever at the speed agree level. Coast to a stop after detection (OT1
fault).
04
Overtorque detection is enabled always. Coast to a stop after detection (OT1 fault).
05
Undertorque detection is enabled whenever at the speed agree level (when inverter is not accelerating
or decelerating). Continue running after detection (UT1 alarm).
06
Undertorque detection is enabled always. Continuing running after detection (UT1 alarm).
07
Undertorque detection is enabled whenever at the speed agree level. Coast to a stop after detection
(UT1 fault).
08
Undertorque detection is enabled always. Coast to stop after detection (UT1 fault)
Summary of Contents for 2001-G+M
Page 2: ......
Page 9: ...C h a p t e r 1 Introduction...
Page 10: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 2 This page intentionally left blank...
Page 16: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 8 This page intentionally left blank...
Page 17: ...C h a p t e r 2 Installation...
Page 18: ...IMPULSE G Mini Advanced Instruction Manual March 2014 2 2 This page intentionally left blank...
Page 25: ...C h a p t e r 3 Wiring...
Page 26: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 2 This page intentionally left blank...
Page 38: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 14 This page intentionally left blank...
Page 39: ...C h a p t e r 4 Getting Started...
Page 40: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 2 This page intentionally left blank...
Page 60: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 22 This page intentionally left blank...
Page 61: ...C h a p t e r 5 Programming Features...
Page 62: ...IMPULSE G Mini Advanced Instruction Manual March 2014 5 2 This page intentionally left blank...
Page 153: ...Troubleshooting IMPULSE G Mini C h a p t e r 6...
Page 154: ...IMPULSE G Mini Advanced Instruction Manual March 2014 6 2 This page intentionally left blank...
Page 165: ...IMPULSE G Mini Advanced Parameter Listing A p p e n d i x A...
Page 166: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 2 This page intentionally left blank...
Page 190: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 26 This page intentionally left blank...