![background image](http://html1.mh-extra.com/html/magnetek/2001-g-m/2001-g-m_instruction-manual_3598661084.webp)
IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-24
C05.03
LC Setting Time
Sets the time to hold the output frequency
allowing the output current/torque to
stabilize.
0.00–2.55
sec
0.15
Adv
C05.04
LC Testing Time
Sets the time (after the LC Setting Time)
for comparing output current/torque to
values for a particular LC Zone being
tested.
0.00–2.55
sec
0.25
Adv
C05.05
LC Acceleration
Margin
Sets the margin for Load Check detection
during acceleration. A setting of 00 is the
most sensitive.
00–50
5
Adv
C05.07
LC Margin
Sets the margin for Load Check detection
at speed agree. A setting of 00 is the most
sensitive.
00–20
5
Adv
C05.08
LC Lowering Speed
Sets the maximum lowering speed after an
LC alarm.
0.1–30.0 Hz
6.0
Adv
C05.09
LC Zone 01
Current/Torque values detected during LC
set up for Zone 01
000–250%
000
Adv
C05.10
LC Zone 02
Current/Torque values detected during LC
set up for Zone 02
000–250%
000
Adv
C05.11
LC Zone 03
Current/Torque values detected during LC
set up for Zone 03
000–250%
000
Adv
C05.12
LC Zone 04
Current/Torque values detected during LC
set up for Zone 04
000–250%
000
Adv
C05.13
LC Zone 05
Current/Torque values detected during LC
set up for Zone 05
000–250%
000
Adv
C05.14
LC Zone 06
Current/Torque values detected during LC
set up for Zone 06
000–250%
000
Adv
C05.15
LC Zone 07
Current/Torque values detected during LC
set up for Zone 07
000–250%
000
Adv
C05.16
LC Zone 08
Current/Torque values detected during LC
set up for Zone 08
000–250%
000
Adv
C05.17
LC Zone 09
Current/Torque values detected during LC
set up for Zone 09
000–250%
000
Adv
C05.18
LC Zone 10
Current/Torque values detected during LC
set up for Zone 10
000–250%
000
Adv
C05.19
LC Zone 11
Current/Torque values detected during LC
set up for Zone 11
000–250%
000
Adv
C05.20
LC Zone 12
Current/Torque values detected during LC
set up for Zone 12
000–250%
000
Adv
C05.21
LC Zone 13
Current/Torque values detected during LC
set up for Zone 13
000–250%
000
Adv
C05.22
LC Zone 14
Current/Torque value detected during LC
set up for Zone 14
000–250%
000
Adv
C05.23
LC Zone 15
Current/Torque value detected during LC
set up for Zone 15
000–250%
000
Adv
C05.24
LC Zone 16
Current/Torque value detected during LC
set up for Zone 16
000–250%
000
Adv
C05.25
LC Integral Time
Integral time used to smooth transitions
0.00–2.55
sec
0.05
Adv
C05.26
LC Delay Time
Load Check delay time for transitions
0.00–2.55
sec
0.25
Adv
C05.27
LC Rev Dir Delay
Minimum delay between Reverse to
Forward transition after Reverse frequency
exceeds C05.28
0.00–2.55
sec
0.00
Adv
C05.28
LC Rev Dir Freq
Minimum frequency that will trigger the
C05.27 delay
0.0–60.0 Hz
30.0
Adv
Parameter
Code
Name
Function
Range
Initial Value
Access
Level
Summary of Contents for 2001-G+M
Page 2: ......
Page 9: ...C h a p t e r 1 Introduction...
Page 10: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 2 This page intentionally left blank...
Page 16: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 8 This page intentionally left blank...
Page 17: ...C h a p t e r 2 Installation...
Page 18: ...IMPULSE G Mini Advanced Instruction Manual March 2014 2 2 This page intentionally left blank...
Page 25: ...C h a p t e r 3 Wiring...
Page 26: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 2 This page intentionally left blank...
Page 38: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 14 This page intentionally left blank...
Page 39: ...C h a p t e r 4 Getting Started...
Page 40: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 2 This page intentionally left blank...
Page 60: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 22 This page intentionally left blank...
Page 61: ...C h a p t e r 5 Programming Features...
Page 62: ...IMPULSE G Mini Advanced Instruction Manual March 2014 5 2 This page intentionally left blank...
Page 153: ...Troubleshooting IMPULSE G Mini C h a p t e r 6...
Page 154: ...IMPULSE G Mini Advanced Instruction Manual March 2014 6 2 This page intentionally left blank...
Page 165: ...IMPULSE G Mini Advanced Parameter Listing A p p e n d i x A...
Page 166: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 2 This page intentionally left blank...
Page 190: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 26 This page intentionally left blank...