![background image](http://html1.mh-extra.com/html/magnetek/2001-g-m/2001-g-m_instruction-manual_3598661122.webp)
IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-62
Parameter
Code
Name
Function
Range
Initial
Value
Access
Level
L01.01
Motor Overload Fault Select
Enable/disable motor overload
detection.
00–03
03
Basic/Adv
00 Disabled
Disables the motor thermal
overload protection
01 Standard Fan Cooled
Selects a motor with limited
cooling capability below rated
(base) speed when running at
100% load. The OL1 function
derates the motor any time it is
running below base speed.
02 Standard Blower
Cooled
Selects a motor capable of
cooling itself over a 10:1 speed
range when running at 100%
load. The OL1 function derates
the motor when it is running at
1/10th of its rated (base) speed or
less.
03 Vector Motor
Selects a motor capable of
cooling itself at any speed when
running at 100% load. Includes
zero speed. The OL1 function
does not derate the motor at any
speed.
L01.02
Motor Overload Time Const
Time for OL1 fault when motor
current is
150% of the motor
rated current. Hot start. See
Figure 5-25.
0.1–5.0 min
1.0
Basic/Adv
L01.03
Motor Overheat Alarm
Selection
Operation when the motor
temperature analog input exceeds
the OH3 alarm level. (1.17V)
(H03.02 or 10 = 0E)
00–04
03
Adv
00 Decel to Stop (Alarm)
01 Coast to Stop (Alarm)
02 Fast Stop by B05.08
(Alarm)
03 Alarm Only (OH3
Flashes)
04 Stop by B03.03 Method
(Alarm)
L01.04
Motor Overheat Fault
Selection
Operation when the motor
temperature analog input exceeds
the OH4 fault level. (2.34V)
(H03.05 or 09 = 0E
00–03
03
Adv
00 Decel to Stop
01 Coast to Stop
02 Fast Stop by B05.08
03 Stop by B03.03 method
L01.05
Motor Temp Filter
Motor temperature analog input
filter time constant
0.00–10.00sec
0.20
Adv
L01.13
Overload Operation
Selection
Determines whether or not to hold
the Electrothermal value when
power is interrupted
00–01
01
Adv
00 Disable
01 Enable
Summary of Contents for 2001-G+M
Page 2: ......
Page 9: ...C h a p t e r 1 Introduction...
Page 10: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 2 This page intentionally left blank...
Page 16: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 8 This page intentionally left blank...
Page 17: ...C h a p t e r 2 Installation...
Page 18: ...IMPULSE G Mini Advanced Instruction Manual March 2014 2 2 This page intentionally left blank...
Page 25: ...C h a p t e r 3 Wiring...
Page 26: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 2 This page intentionally left blank...
Page 38: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 14 This page intentionally left blank...
Page 39: ...C h a p t e r 4 Getting Started...
Page 40: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 2 This page intentionally left blank...
Page 60: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 22 This page intentionally left blank...
Page 61: ...C h a p t e r 5 Programming Features...
Page 62: ...IMPULSE G Mini Advanced Instruction Manual March 2014 5 2 This page intentionally left blank...
Page 153: ...Troubleshooting IMPULSE G Mini C h a p t e r 6...
Page 154: ...IMPULSE G Mini Advanced Instruction Manual March 2014 6 2 This page intentionally left blank...
Page 165: ...IMPULSE G Mini Advanced Parameter Listing A p p e n d i x A...
Page 166: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 2 This page intentionally left blank...
Page 190: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 26 This page intentionally left blank...