My meter "
Total
" isn't right
Symptom
Cause
Remedy
My meter total "creeps" up
Normally occurs due to moving
water - leaky gate, foot valve
Check seals of gates and
valves. Consider installing a
second gate to isolate the sys-
tem.
Entrapped aquatic life in pipe
Adjust "
" using
Water "sloshing" in pipe around
sensor level
Make sure water level recedes
fully, or pipe stays completely
full. Consider installing a
second gate to isolate the sys-
tem.
Electromagnetic interference
(EMI) causing false "flow"
Find source of EMI and rectify
if possible
My total is not increasing
Total channel set up as "
Neg-
ative only
"
Check "
" in
My total is not decreasing
Total channel set up as "
Pos-
itive only
"
Check "
" in
I can't reset the total
Total channel has been set up
as "
Non-resettable
"
Check "
" in
My total "rolls over" too
quickly
Total units are too small for
application
Change
to larger
units
My total is wrong!
Total units are not what's expec-
ted
in
Total has "rolled over" without
me realising it!
MACE XCi User Manual - 222 -
Summary of Contents for HVFlo XCi
Page 1: ......
Page 10: ...MACE XCi User Manual 10...
Page 18: ...MACE XCi User Manual 18...
Page 21: ...MACE XCi User Manual 21...
Page 50: ...MACE XCi User Manual 50...
Page 98: ...MACE XCi User Manual 98...
Page 173: ...MACE XCi User Manual 173...
Page 178: ...MACE XCi User Manual 178...
Page 211: ...For a short video of the procedure click Play MACE XCi User Manual 211...
Page 238: ...3 Unscrew the locking ring using the tool and remove completely MACE XCi User Manual 238...
Page 239: ...4 Remove the damaged ceramic depth sensor MACE XCi User Manual 239...
Page 250: ...MACE XCi User Manual 250...