This real-time graph displays an ideal “bell shape” centred across the velocity range. The range has been
set to double the average velocity. This enables all velocities across the range to be captured.
This real-time graph displays a situation where the velocity range has not been set correctly for the site
conditions. Velocities exceeding the set range are not being captured. Furthermore, the velocity readings
that are missed WILL cause the processing electronics to alias and the overall average velocity
calculated will be unreliable. The range MUST be set to at least double the average velocity. This
enables all velocities across the range to be captured.
Factors affecting the velocity sensor
This chapter is designed to give the operator a brief understanding of some of the factors affecting the
performance of the MACE Doppler ultrasonic velocity sensor/s.