NOTE: Straight run requirements listed are "theoretical" minimums. In certain
applications, more or less straight run may be applicable. If unsure about your
specific site, please do not hesitate to consult your local MACE representative.
Where is the best place to mount the sensor in a Full pipe?
The sensor should be mounted on the side wall of the pipe, between the 2 and 5 o’ clock positions. A ball
valve should be used when mounting “
Insert
” type sensor to allow for easy maintenance.
WARNING: Don’t mount the sensor at the top of the pipe as air pockets could give
unreliable readings. Don’t mount the sensor at the bottom of the pipe as silt build-up
can cover the sensor. Only mount the sensor between 2 and 5 o’clock as shown
above.
Where is the best place to mount the sensor in a partially full pipe or channel?
The sensor must be mounted such that the depth sensor is always covered by water to a depth of at least
50mm (2 inches).
MACE XCi User Manual - 30 -