Symptom
Cause
Remedy
Integration period not long
enough to collect data
Increase "
Insufficient acoustic targets at
site
Read "
"
guidelines
My meter IS reading flow
when it's NOT flowing!
Normally occurs due to moving
water - leaky gate, foot valve
Check seals of gates and valves
Entrapped aquatic life in pipe
Adjust "
" using
Water "sloshing" in pipe around
sensor level
Make sure water level recedes
fully, or pipe stays completely
full
Electromagnetic interference
(EMI) causing false "flow"
Find source of EMI and rectify if
possible