10. Now that the insertion depth is correct, rotate the sensor so that the grub screw at the top of the
sensor shaft is roughly pointing in the direction of the longest straight section of pipe. Locate the
plastic direction indicator tool that was supplied with the sensor. Clip the tool onto the stem of the
insert sensor so that it is located in the two "blind holes" at the top of the stem with the grub screw
facing the direction of the arrow.
NOTE: The grub screw indicates the velocity sensing face.
11. Sighting along the axis of the direction indicator tool, ensure that the sensor is
exactly parallel
with
the axis of the pipe.
WARNING: Remember you
must
have a distance of at least six pipe
diameters of straight pipe in front of the sensor and two pipe diameters of
distance behind the sensor.
WARNING: According to AS4747 and NMI M10 Pattern Approval certification,
the sensor
must
have a distance of at least 20 pipe diameters of straight pipe
in front of the sensor and five pipe diameters of distance behind the sensor
when positioned after a pump or two out-of-plane elbow fittings.
MACE XCi User Manual - 37 -
Summary of Contents for HVFlo XCi
Page 1: ......
Page 10: ...MACE XCi User Manual 10...
Page 18: ...MACE XCi User Manual 18...
Page 21: ...MACE XCi User Manual 21...
Page 50: ...MACE XCi User Manual 50...
Page 98: ...MACE XCi User Manual 98...
Page 173: ...MACE XCi User Manual 173...
Page 178: ...MACE XCi User Manual 178...
Page 211: ...For a short video of the procedure click Play MACE XCi User Manual 211...
Page 238: ...3 Unscrew the locking ring using the tool and remove completely MACE XCi User Manual 238...
Page 239: ...4 Remove the damaged ceramic depth sensor MACE XCi User Manual 239...
Page 250: ...MACE XCi User Manual 250...