UNLOADING AND ASSEMBLY
Form 169542
53
Revision F
STEP 21. START ENGINE
a. Check fuel level, and if require d add sufficient
fuel for a 15 minute run.
b. Lock (A) should be engaged at cab-forward or
engine-forward position (M155 and M205 only).
c. Move GSL (B) into N-DETENT.
d. Turn steering wheel until it locks.
e. Push HEADER DRIVE switch (C) to OFF.
f.
Normal Start (All Engines):
engine temperature
above 60°F (16°C).
1. Set throttle to START position (D) - fully back.
CAUTION
Check to be sure all bystanders have cleared
the area.
2. Sound horn (E) three times.
3. Turn ignition key (F) to RUN position.
4. Single loud tone sounds, and engine warning
lights illuminate, and CDM displays “HEADER
DISENGAGED” and “IN PARK”.
WARNING
If starter engages with steering wheel
unlocked, ground speed lever out of
NEUTRAL, or header clutch engaged, DO NOT
START ENGINE. See your Dealer.
5. Turn ignition key (F) to START position until
engine starts, and then release key. Tone
ceases, and warning lights go out.
IMPORTANT
Do not operate starter for longer than
15 seconds at a time.
If engine does not start, wait at least
two minutes before trying again.
After the third 15 second crank attempt,
allow starter motor to cool for 10
minutes before further cranking
attempts.
If engine still does not start, refer to the
following table:
PROBLEM SOLUTION
Controls Not In NEUTRAL.
Move GSL to NEUTRAL.
Move steering wheel to
locked position.
Disengage header clutch.
Operator’s Station Not
Locked.
(M155 and M205 only).
Adjust position of Operator’s
station.
Ensure lock is engaged.
Neutral Interlock
Misadjusted.
Contact MacDon Dealer.
No Fuel To Engine.
Fill empty fuel tank.
Replace clogged filter.
Old Fuel In Tank.
Drain tank.
Refill with fresh fuel.
Water, Dirt Or Air In Fuel
System.
Drain, flush, fill and prime
system.
Improper Type Of Fuel.
Use proper fuel for operating
conditions.
Crankcase Oil Too Heavy.
Use recommended oil.
Low Battery Output.
Have battery tested. Check
battery electrolyte level.
Poor Battery Connection.
Clean and tighten loose
connections.
Faulty Starter.
Contact MacDon Dealer.
Wiring Shorted, Circuit
Breaker Open.
Check continuity of wiring
and breaker (manual reset).
Faulty Injectors.
Contact MacDon Dealer.
(continued next page)
A
B
E
M105
E
M155, M205
F
B
C
D
Summary of Contents for M 2009 Series
Page 2: ...Form 169242 2 Revision E MACDON M SERIES SELF PROPELLED WINDROWER ...
Page 90: ...UNLOADING AND ASSEMBLY Form 169242 Revision F 90 continued next page ...
Page 92: ...UNLOADING AND ASSEMBLY Form 169242 Revision F 92 continued next page ...
Page 93: ...UNLOADING AND ASSEMBLY Form 169242 Revision F 93 continued next page ...
Page 94: ...UNLOADING AND ASSEMBLY Form 169242 Revision F 94 ...