6.1 Supported TLS DE Data Types
6.1.1 Extended error message DE-Type 14
If configured (see „Uplink“ configuration above), the error code reported by the UMB
device for a channel is transmitted as a supplier-defined byte in the DE-Type 14 error
message.
Besides the default UMB error codes, following values are possible:
0xF1 : general error (e.g. communication error with UMB device)
0xF2 : range check failed
0xF3 : freezing temperature cannot be determined (only for freezing temperatures
– if
configured)
0xF4 : no measure value available
0xF5 : UMB power shutdown (only if UMB PowerSaver is active and battery power is
below threshold)
0xF6: error calculating the value for a virtual/calculated sensor channel
6.1.2 FG3
6.1.2.1 Standard data types FG3
All types described in TLS Standard 2012 are supported. These are:
Type
Description
48
Air temperature LT
49
Road Surface Temperature FBT
52
Residual Salt RS
53
Precipitation Intensity NI
54
Air Pressure LD
55
Relative Humidity RF
56
Wind Direction WR