numDGTRoadConditionAlarmCodeEntries: number of DGT Road Condition
alarm code entries in the respective table.
•
numSandStormDetectionEntries: number of Sand Storm Detection results in
the respective table.
•
numWetSpotDetectionEntries: number of Wet Spot Detection results in the
respective table.
•
numBatteries: number of batteries in the instrumentation.batteryStatus table
(see next chapter)
•
numDoors: number of doors in the instrumentation.doorStatus table (see next
chapter).
•
spectroTableNumSensors: number of entries in vaiRwsRelease.spectroTable
•
hseIceSightTableNumSensors: number of entries in hseIceSight.iceSightTable
•
numRadarRainSensors: number of entries in the radarRainSensorTable
(which provides all native UMB sensor channels of the R2S radar rain sensor)
•
numAllInOneSensors: number of entries in the allInOneSensorTable (which
provides all native UMB sensor channels of the WSx all in one sensor)
•
dataStore
– storeEnabled: enable/disable the NTCIP data store
•
maxNumOid: maximum number of sensor OIDs that can be stored. Defaults to
128.
Note: the maximum number of OIDs that can be used in the datastore
depends on 2 factors: a) available space on the SD card, and b) MTU size of
the network connection used to communicate with the device (since data
for all configured sensors is transmitted in one OctetString parameter with
size 4 * number of OIDs, which in turn is sent in one UDP packet / one MTU).
Typical MTU size is >= 576 byte, i.e. up to 128 OIDs should not cause any
problems.
5.8.2.12.1
noninvasive/passive/activeRoadSensorTable