![Lufft 8511.EAK Operating Manual Download Page 27](http://html1.mh-extra.com/html/lufft/8511-eak/8511-eak_operating-manual_1947031027.webp)
5.7.2 TLS LOKALBUS/INSELBUS Parameter
TLS TC57/Inselbus/AUSA parameters: The timing parameters for Inselbus
communication are site and line-dependent and must be adjusted if necessary.
•
Wait time: The time waited after receiving an error-free telegram before
sending the next telegram (response).
•
Pre-Carriage time: time/delay between switching on the carrier signal and
sending the first telegram byte.
•
Post-Carriage time: (additional parameter, not specified in the standard);
time/delay after sending the last byte of the telegram, before switching off the
carrier signal.
•
Send Class1 data on RQD2: Controls whether data of transmission class 1 are
also transmitted on RQD2 requests from the exchange (DE error messages
and FG6 data in FG6 “Change” mode) (RQD2 is then treated as RQD3)
•
RS232: Parameter for serial connection.
For Inselbus: baud=1200, parity=E, data=8, stopp=1
For Lokalbus: baud=9600, parity=E, data=8, stopp=1
Default values are set when Uplink protocol is changed.