Multiple instances for the model calculation can be configured (in case the station is
equipped with more than one road sensor).
Note: the default values are preset for the (German) TLS protocol, e.g. the “Dewpoint
diff” value of 5.0 refers to 0.5 °C as the temperatures for TLS are in 1/10 °C.
Please adjust the parameters as needed for the sensor channels configured here.
•
Active: this instance of the model calculation is active
•
Dewpoint Diff: the value that the road temperature must be below the dew
point temperature for “slippery frosty” to be set (see above)
•
Road Condition Dry: the road condition code for “dry”
•
Slippery Frosty: the road condition code for “slippery frosty”
•
Road Condition: the road condition sensor channel
•
Road Temperature: the road temperature sensor channel
•
Water Film: the water film sensor channel
•
Dew point: the dew point sensor cannel