Manual
LCom
Page 121 of 158
(depending on the configured input channels) calculates a simulated (“expected”)
value for the water film from precipitation intensity, air temperature and humidity.
The parameters are as follows:
•
Waterfilm:
the waterfilm as measured by the road sensor (in mm)
•
Scale:
a scale factor to convert the waterfilm to mm if the input channel does
not report the waterfilm in mm (e.g. a TLS coded input channel)
•
Precip. Intensity:
the precipitation intensity (in mm/h)
•
Scale:
a scale factor to convert the precipitation intensity to mm/h if the input
channel does not report the precipitation intensity in mm (e.g. a TLS coded
input channel).
•
Air Temperature:
the air temperature (in °C)
•
Scale:
a scale factor to convert the air temperature to °C if the input channel
does not report the air temperature in °C (e.g. a TLS coded input channel)
•
Rel. Humidity:
relative humidity (in %)
•
Waterfilm Time Factor:
a time factor used in calculating the smoothed water
film height
•
Waterfilm Decrease Delay:
a decrease delay used in calculating the
smoothed water film height