13

206-4218

Rack Installation (Cont.)

Rack-mount Considerations

A. Elevated Operating Ambient

 

If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack 

environment may be greater than room ambient. Therefore, consideration should be given to 

installing the equipment in an environment compatible with the maximum ambient temperature 

(Tma) specified by the manufacturer (see Specifications information in this document).

B. Reduced Air Flow

 

Installation of the equipment in a rack should be such that the amount of air flow required for 

safe operation of the equipment is not compromised. To ventilate the system normally and 

avoid overheating, leave at least 1 inch (2.5 cm) on each side (including top and bottom) of 

the OAT100R. Do NOT stack other equipment on the top of the OAT100R. Also, if multiple 

OAT100R units are to be installed in close proximity, for example, in one rack, ensure that the 

units’ AC power adapters are never stacked or bundled. Each adapter should have adequate 

ventilation and should be isolated from other heat sources.

C. Circuit Overloading

  Consideration should be given to the connection of the equipment to the supply circuit and the 

effect that overloading of the circuits might have on overcurrent protection and supply wiring.

D. Reliable Earthing

  Maintain reliable earthing of rack-mounted equipment. Particular attention should be given to 

supply connections other than direct connections to the branch circuit (e.g., use of power strips). 

E. Mains Outlet Earthing

  The apparatus with Class I construction must be connected to a mains socket outlet with a 

protective earthing connection.

PWR   STATUS

SERVICE

PORT

Front View 

of Rack Cabinet

1 inch minimum

1 inch minimum

Summary of Contents for CodePlus OAT100R

Page 1: ... Copyright 2013 LG Electronics U S A Inc CodePlus OAT100R Off Air Transcoder System Installation Setup Guide Warranty P N 206 4218 Rev B ...

Page 2: ...ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envi ronment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference...

Page 3: ... apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 14 Power Sources This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supply to your INSTALLATION consult your product dealer or local power company 15 Overloading Do not overload wall power outlets and ext...

Page 4: ...ts specified by the manufacturer or that have the same characteristics as the original parts Unauthorized substitutions may result in fire electric shock or other hazards 24 Safety Check Upon completion of any service or repairs to this product ask the service technician to perform safety checks to determine that the product is in proper operating condition OAT100R Rack Installation also see pages...

Page 5: ...n overcurrent protection and supply wiring D Reliable Earthing Maintain reliable earthing of rack mounted equipment Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips E Mains Outlet Earthing The apparatus with Class I construction must be connected to a mains socket outlet with a protective earthing connection OAT1...

Page 6: ...3 38 Access the OAT100R Web GUI 23 OAT100R System Status 24 Tuner Information 25 Tuner Menu Options 26 Input Channel Options 28 OAT100R System Setup Options 30 MUX Setup Options 35 OAT100R Maintenance Options 36 Configuration Options via Command Line 39 66 Log In to the OAT100R and Access the Main Menu 39 View System Information 40 Monitor the System 40 View the System Program Map 41 Tuner Menu Co...

Page 7: ... eight programs per tuner input This capability provides output of up to 32 programs IP output The OAT100R provides up to eight multicast streams with support for up to eight programs each if provided in the original broadcast Provides one MPEG 2 video output with up to two AC3 audio outputs per program Supports any QAM compatible television Transcoded output supports Closed Captions and V Chip Pa...

Page 8: ...itional equipment i e attenuators may be required to adjust the signal level OAT100R __ Unpack the OAT100R unit and all accessories OAT100R Accessories AC Power Cord and Adapter __ Select the location for mounting the OAT100R Ensure that adequate ventilation is available __ Obtain the necessary attachment hardware to mount the OAT100R chassis in its targeted location __ Plan and install the necess...

Page 9: ...start channel assignment is 227 0 0 40 the remaining channels will be 227 0 0 41 227 0 0 42 etc Or you may opt to manually specify the IP details for each IP channel __ Reserve at least one User Datagram Protocol UDP port for the multicast data streams You can use the system default 1234 or another unassigned port number for each data stream as required for example 50000 50001 etc The port s must ...

Page 10: ...ream data such as audio or video etc Typical transport streams contain one PID for the PAT as well as three or more PIDs for each program one for PMT one for video and one or more for audio The PIDs used for each elementary stream must be unique to allow receivers to properly demultiplex Pro Idiom adds a third PID type to each PMT The Pro Idiom message PID may fall anywhere in the range 0x0010 to ...

Page 11: ...he AC mains plug is used as the disconnect device The disconnect device must remain readily operable STATUS LED POWER LED STATUS SERVICE PORT PWR USB Port Service Port OAT100R Rear View OAT100R Front View Ventilation Holes Air flow must not be obstructed To ventilate the system normally and avoid overheating leave at least 1 inch 2 5 cm on each side including top and bottom of the OAT100R Do NOT s...

Page 12: ...wish to change the location orientation of the mounting brackets carefully remove each of the four M4 x 10 mm screws and attendant washers one flat and one lock washer per screw holding each bracket in place Then use the same screws and washers to reattach the mounting brackets in the desired location 2 Carefully slide the chassis into a standard 19 inch equipment rack 3 Use all four mounting scre...

Page 13: ...o NOT stack other equipment on the top of the OAT100R Also if multiple OAT100R units are to be installed in close proximity for example in one rack ensure that the units AC power adapters are never stacked or bundled Each adapter should have adequate ventilation and should be isolated from other heat sources C Circuit Overloading Consideration should be given to the connection of the equipment to ...

Page 14: ...pical Setup Flow Chart for OAT100R with RF Output VHF UHF Antenna s OAT100R Feature Port Control Port Laptop PC Service Port Connection Network RF IN 8 RF IN 7 RF IN 6 RF IN 5 RF IN 4 RF IN 3 RF IN 2 RF IN 1 RF Cable RF Distribution Network Room Receiver Room Receiver Room Receiver RF Out OAT100R Laptop PC Service Port Connection RF IN 8 RF IN 7 RF IN 6 RF IN 5 RF IN 4 RF Out Use multiple antennas...

Page 15: ...ction Network RF IN 8 RF IN 7 RF IN 6 RF IN 5 RF IN 4 RF IN 3 RF IN 2 RF IN 1 RF Out Room Receiver Room Receiver Room Receiver Use multiple antennas or an amplifier splitter as necessary Up to eight antenna signals may be connected Use multiple antennas or an amplifier splitter as necessary Up to eight for 256 QAM output or four for 64 QAM output antenna signals may be connected System Setup Cont ...

Page 16: ...ntact your service representative for further information 4 Connect the OAT100R power supply to the POWER connector on the OAT100R rear panel Then plug the AC power cord into a powered AC line receptacle When power is applied the PWR Power LED on the OAT100R front panel will initially flash red and then turn green The boot up process for the OAT100R may take up to two minutes When boot up is compl...

Page 17: ... If the Ctrl IP field shows an IP address the OAT100R is up and running on the network Continue with step 10 If the network is configured for DHCP but the Ctrl IP field is blank refer to Network Setup troubleshooting information on page 67 If the network is not configured for DHCP you will need to configure a static IP address for the OAT100R Complete steps 10 to 13 as required and then set the OA...

Page 18: ...ptions for configuring output IP channels To manually configure the output IP channels use the set command You will need to specify a multicast IP address and the multicast port number for each tuner To auto configure output IP channels from a base multicast IP address and port number use the fill command Once you enter the base multicast IP address and the multicast port number the system will au...

Page 19: ...y establish remote communication with the OAT100R and then continue with step 16 Note that you may use the GUI to perform the configuration steps if desired Refer to Network and Communication Setup on page 22 for information on establishing remote communication with the OAT100R and or Configuration Options via GUI on pages 23 to 38 for further information on the GUI 16 Required only if Pro Idiom c...

Page 20: ...tional three tuners as required Note Use the tuner command as described on page 43 to access the Tuner Menu for each of the tuners in turn e When you are finished mapping the last tuner stream at the Tuner Command prompt type exit and press Enter to return to the Main Menu Command prompt 19 Optional As part of the system setup you will need to set tuner channel and program numbers If you are not s...

Page 21: ...fields in the Tuner Information display SNR To avoid interference the signal to noise ratio should be greater than 18 FEC Errors There should be zero 0 forward error correction FEC errors Locked The tuner should be locked to the antenna signal If any of these fields shows a value that is NOT in accordance with the specifications above refer to Receiver Reception troubleshooting information on page...

Page 22: ...ar panel Using HyperTerminal or an equivalent terminal emulation program on the PC configure the serial port as follows Bits per second baud 115200 Data bits 8 Parity None Stop bits 1 Flow Control None OAT100R configuration options via web GUI are described on pages 23 to 38 OAT100R configuration options via command line are described on pages 39 to 66 For security and control purposes some option...

Page 23: ...type admin in the Password field type the admin user password Then click OK The OAT100R web GUI opens with the System Status on display see OAT100R System Status on the next page for further information The options panel at the left of the screen enables you to view and configure system settings The following sections provide detailed information on the configuration settings and commands Note It ...

Page 24: ...he Tuner Menu for the selected tuner Also you can click on an RF channel number or multicast IP address depending on the output mode to access the System Setup screen and menu options for the OAT100R Refer to Tuner Menu Options on pages 26 to 28 for information on the Tuner Menu and OAT100R System Setup Options on pages 30 to 34 for information on the System Setup display and menu options To view ...

Page 25: ... tuners may be mapped to these streams see MUX Setup Options on page 35 for further information Tuner Information Note In both the System Status and Tuner Information screens the site location if specified in the System Setup screen or in the command line interface Setup Menu is identified in blue text to the right of the screen title For each tuner the Tuner Information screen identifies the tune...

Page 26: ... to view and or modify tuner configuration To access the Tuner Menu for a selected tuner either Click on the desired tuner channel number in the System Status or Tuner Information screen or Click on Tuner Menu in the options panel at the left of the screen and then select the appropriate tuner number from the submenu see example below On the left side of the Tuner Menu screen an Information sectio...

Page 27: ... Note If the system is set for RF 64 QAM output up to four tuners can be used at a time 1 Click on the down arrow at the right of the Channel Number field and select either the desired channel number or N C no connection from the drop down list of options 2 Click on the Set button at the right of the field If the channel is set successfully the system will display at the bottom of the Tuner Inform...

Page 28: ...ut Program column to confirm your settings If you successfully set the program mapping parameters the system will display at the bottom of the Tuner Information display Power the Tuner On or Off In the Tuner Power section of the Tuner Menu screen you can power ON or power OFF the tuner To power ON the tuner click on the On button To power OFF the tuner click on the Off button In each case if the a...

Page 29: ...RF channels 2 Click on the Scan button to initiate the scan The RF scan will take several minutes When the scan is complete the system provides a listing of the channels found for the selected tuner s Note If multiple tuners are connected to one antenna you do not need to run separate RF scans on each Note If the system is set for RF 64 QAM output up to four tuners can be used at a time Make sure ...

Page 30: ...menu options are available as described in the following subsections Configure the Program PIDs If any Pro Idiom channels are configured in the site s entertainment system you must configure program PIDs for the OAT100R output in the Program PID section of the System Setup screen See Packet Identifiers PIDs Overview on page 10 for further information and or check with your service representative i...

Page 31: ...31 206 4218 Typical System Setup Screen Configuration Options via GUI Cont ...

Page 32: ...t button below the Secondary DNS IP Address field If you successfully changed the IP configuration of the Control Port the system will display at the bottom of the System Information display The System Information display will also show the new Control Port IP address if applicable 5 Click on the Reset button in the System Reset section of the System Setup screen if you are ready to reset the syst...

Page 33: ...F start channel number The remaining three channels will be automatically assigned per EIA 542 STD CATV frequency allocation standards IP output configuration For each IP channel stream type the appropriate multicast IP address and port number in the IP Address and IP Port fields respectively Note If you would like the OAT100R to auto increment IP channels from a base multicast IP address you will...

Page 34: ...time for the OAT100R Click on the down arrow at the right of each field Year Month Day Hour Minute to select the appropriate value from the drop down list of options 4 When you have completed the fields as required click on the Set button at the bottom of the Time Configuration section If you successfully changed the OAT100R time configuration the system will display at the bottom of the System In...

Page 35: ... assignments click on the Reset button at the bottom of the Stream column The tuner output assignments will be reset immediately Modify Tuner Output Assignments This option enables you to reconfigure tuner output assignments Note that each tuner can only be assigned to one output stream For example If Tuner 1 is currently streaming on Stream 1 you cannot map Tuner 1 to any additional streams To re...

Page 36: ...onfirmation of the changes Either Click OK to confirm and apply the new assignments Click Cancel to return to the MUX Setup screen without saving your changes If you successfully change the tuner output assignments the system will display below the MUX Setup screen This operation typically takes up to 20 seconds OAT100R Maintenance Options The Maintenance screen enables you to update firmware and ...

Page 37: ...t updating the OAT100R firmware If you opt to proceed the system will initiate the firmware update and progress and results messages will be displayed in the Result section at the bottom of the screen for example 4 When the firmware update is finished click on the Reset button in the System Reset section of the Maintenance screen to reset the system see Reset the System on the following page for f...

Page 38: ...indow prompting for confirmation Either Click OK to initiate a reset of the OAT100R The reset process during which each of the tuners will also be reinitialized may take up to two minutes after which the system resumes normal operation Click Cancel to return to the Maintenance screen without resetting the OAT100R Configuration Options via GUI Cont ...

Page 39: ...uld see a login prompt If the login prompt is not automatically displayed press Enter to refresh the screen 2 At the login as prompt type admin and press Enter 3 At the password prompt type the admin user password and press Enter 4 At the Command prompt either Press Enter to display the OAT100R Main Menu see example below Type the desired command and press Enter The following sections describe eac...

Page 40: ...ll show IP and RF fields will not be present Also the Location field is only present if the site location has been specified either in the GUI System Setup screen or in the command line interface Setup Menu It is recommended that you record this information for future reference If you find it necessary to call customer service or engineering support please have this information available Monitor t...

Page 41: ... 0 Yes 18 2 8 6 11 Use a parameter for auto refresh e g type monitor 1 View the System Program Map 1 Log in to the OAT100R as described on page 39 2 At the Command prompt type map and press Enter The System Program Map display shows program assignments for each tuner for example SYSTEM PROGRAM MAP Date 2012 10 17 12 28 41 SN 201 12301011 Version 1 9 HWID 11 20 Output RF 64 QAM B Tun RF In Prog Str...

Page 42: ...tuner and then displays a Tuner command prompt for example Current Tuner Tuner 1 Tuner 1 Command 4 At the Tuner Command prompt either Press Enter to display the Tuner Menu see example below Type the desired command and press Enter Note You can always press Enter at the Tuner Command prompt to display the Tuner Menu Example Tuner Menu Tuner Menu tuner Change Tuner info Tuner info monitor System mon...

Page 43: ... status and configuration data for example Tuner 1 Info Power On Status Streaming Channel 7 SNR 32 9 FEC errors 0 Signal lock Yes Bitrate 19 4 Output 7 Program selection Program 1 1 Program 2 2 Program 3 3 Program 4 NC Program 5 NC Program 6 NC Program 7 NC Program 8 NC Under standard operating conditions a powered tuner should be streaming see also note on following page In addition the tuner sho...

Page 44: ...resh the data every second type monitor 1 and press Enter When you are finished monitoring streaming data press Enter to stop the system monitor and return to the Tuner Command prompt View the System Program Map This option enables you to display program assignments for each tuner and is also available from the OAT100R Main Menu and the Setup Menu At the Tuner Command prompt type map and press Ent...

Page 45: ... assignments as desired using the prog command described below Program Mapping 1 At the Tuner Command prompt type prog and press Enter The system displays the current program settings and then displays the first of a series of prompts for each input program for example Current program selection Program 1 1 Program 2 2 Program 3 3 Program 4 NC Program 5 NC Program 6 NC Program 7 NC Program 8 NC Cha...

Page 46: ...to the Tuner Command prompt without changing the program configuration Configure Tuner Output Assignments This option enables you to reconfigure tuner output assignments Note that each tuner can only be assigned one output stream If you remap an existing stream assignment to another tuner the initial assignment will be disconnected For example If Tuner 1 is currently streaming on Output 1 and Tune...

Page 47: ...tings Refer to Monitor the System on page 44 for further information Power the Tuner On or Off At the Tuner Command prompt either Type on and press Enter to power ON the tuner The system will display confirmation for example Powering on Tuner 1 OK Note that the power ON process may take up to 90 seconds as tuner firmware is reloaded If desired you can track the tuner progress via the Tuner Menu in...

Page 48: ...xample below Type the desired command and press Enter Note You can always press Enter at the Setup Command prompt to display the Setup Menu Example Setup Menu Setup Menu info System information monitor System monitor map System program map omode Set output mode pid System PID configuration proidiom Pro Idiom configuration setip Control port IP configuration menu rf RF output configuration scan Sca...

Page 49: ...n real time type monitor and the number of seconds before the data refreshes Then press Enter For example to refresh the data every second type monitor 1 and press Enter When you are finished monitoring streaming data press Enter to stop the system monitor and return to the Setup Command prompt View the System Program Map This option enables you to display program assignments for each tuner and is...

Page 50: ...eck with your service representative if necessary 1 At the Setup Command prompt type pid and press Enter The system displays an overview of the current PID configuration including Pro Idiom PIDs followed by a prompt for the starting program PID for example Current PID Configuration Program PIDs range 0x30 0x6f Pro Idiom PIDs range 0x1050 0x1057 Send Pro Idiom messages no Enter the starting program...

Page 51: ...the password otherwise if necessary obtain the password from the system administrator 1 At the Setup Command prompt type proidiom and press Enter 2 At the Enter Pro Idiom user password prompt type the password case sensitive and press Enter The system displays an overview of the current PID configuration including program PIDs followed by a prompt for the starting Pro Idiom PID for example Current...

Page 52: ...uration has been saved Type n and press Enter to return to the Setup Command prompt without saving your changes Configure the Control Port 1 At the Setup Command prompt type setip and press Enter The system displays an overview of the current TCP IP network configuration followed by the Network Configuration Menu for example Current Network Configuration Interface controller port Host name oat100r...

Page 53: ...st IP address in the format xxx xxx xxx xxx Network mask Type the netmask in the format xxx xxx xxx xxx Gateway IP address Type the IP address of the default gateway in the format xxx xxx xxx xxx 7 Once you enter the gateway IP address the system will redisplay the Network Configuration Menu To modify the DNS configuration continue with step 8 If no additional network configuration is required go ...

Page 54: ... further information Note If you intend to modify additional configuration settings during the current session you may wait until all changes are complete before you reset the system Configure the RF Output This option enables you to specify the appropriate RF channels for your location See Channel Assignments for RF Output on pages 8 and 9 and or check with your service representative if necessar...

Page 55: ...or type the applicable number of channels Maximum 4 Once you specify the RF setup the system displays an overview of the settings for example RF config Mode 2 256 QAM B RF 6 MHz 5 36 MSps RF channels 7 8 9 10 Scan for RF Channels This option enables you to select up to two tuners at a time and initiate a scan for all available off air RF channels Note If multiple tuners are connected to one antenn...

Page 56: ...e scan is complete the system displays a listing of the channels and programs found for the selected tuner s for example Channel scan completed successfully Scan found a total of 10 channels Channel 7 programs 1 2 3 Channel 12 programs 1 Channel 17 programs 3 5 Channel 19 programs 3 4 Channel 21 programs 1 2 3 Channel 27 programs 3 4 5 6 7 Channel 36 programs 1 2 4 Channel 43 programs 3 4 5 100 10...

Page 57: ... Menu when you are finished reviewing the display Manually Configure Output IP Channels This option enables you to specify the multicast IP address and port number for each program Each program must be assigned a unique IPv4 multicast address See Channel Assignments for IP Output on page 9 and or check with your service representative if necessary Note If you wish to set a base multicast IP addres...

Page 58: ...be assigned a unique IPv4 multicast address See Channel Assignments for IP Output on page 9 and or check with your service representative if necessary Note If you wish to manually configure each IP channel use the set option described above 1 At the IP Output Command prompt type fill and press Enter 2 At the Enter base multicast IP address 227 0 0 0 command either press Enter to accept the default...

Page 59: ...r that corresponds to the appropriate option for your location and then press Enter 4 The system will display the following prompt for a country followed by a list of options Please select a country At the prompt type the number that corresponds to the appropriate option for your country and then press Enter 5 The system will display the following prompt for a region followed by a list of options ...

Page 60: ...riodically update the time setting on the OAT100R If the OAT100R is not connected to the Internet you also have the option to disable NTP client synchronization and specify date and time data manually Refer to Set the Time Zone on the previous page for information on setting the time zone 1 At the Setup Command prompt type time and press Enter 2 At the Use NTP for time synchronization Y N Y prompt...

Page 61: ...or confirmation for example New time 2012 10 17 18 53 00 Apply y n Either type y and press Enter to apply the new configuration to the system or type n and press Enter to return to the Setup Command prompt without changing the time configuration If you do apply new manual configuration the system will display confirmation for example New time is set Change the Login Password 1 At the Setup Command...

Page 62: ...cept the default value in brackets or type in the number of a known good channel to test and press Enter The system will prompt for confirmation This is a diagnostic routine that may only be run in a controlled environment such as the factory Are you sure you want to continue y n y n 3 Either Type y and press Enter to initiate the diagnostic routine When testing is complete the system will display...

Page 63: ...ystem will display confirmation for example Location description has been set Type n and press Enter to return to the Setup Command prompt without specifying a location Exit the Setup Menu At the Setup Command prompt type exit and press Enter to exit the Setup Menu and return to the OAT100R Main Menu Command prompt Reset the System This command is also available from the OAT100R Main Menu 1 At the...

Page 64: ...cfg Configure update server exit Return to the main menu Update Command Update OAT100R Firmware via Ethernet This option enables you to update OAT100R firmware via the Ethernet The appropriate update file must be provided by LG the system will not download an improper file Note See Update OAT100R Firmware via Serial Link below for information on updating firmware via a serial link 1 At the Update ...

Page 65: ...s 3 When the update is successfully completed exit the Update Menu and reset the system see Reset the System on page 66 for further information Configure the Update Server 1 At the Update Command prompt type ucfg and press Enter 2 At the Enter update protocol ftp or tftp ftp prompt either press Enter to accept the default value i e the current setting in square brackets or type the new update prot...

Page 66: ...set the system y n 3 Either Type y and press Enter to initiate an immediate reset of the OAT100R The reset process during which each of the tuners will also be reinitialized may take up to two minutes after which the system resumes normal operation Type n and press Enter to return to the Command prompt without resetting the system Exit the Current Session At the Main Menu Command prompt type exit ...

Page 67: ...es red and then turns green When the OAT100R is booted and operating normally the STATUS LED is continuously lit green Network Setup If the network is configured for DHCP but the OAT100R has not been assigned an IP address i e the Ctrl IP field in the OAT100R System Information display is blank 1 Check the Control Port connector on the rear panel of the OAT100R Make sure the cable connection is ti...

Page 68: ...e that the OAT100R and PC IP addresses are not on the 192 168 0 x subnet which is reserved for internal communication No Yes End Check that the proper IP address for the OAT100R is being targeted If necessary adjust and then reattempt communication To verify the OAT100R IP address If DHCP is enabled check the router for DHCP IP address assignments to determine whether the proper IP address is bein...

Page 69: ...se ratio should be greater than 18 there should be zero 0 FEC errors and the input bitrates should equal 19 4 Mbps For example Check the antenna cabling Ensure that each cable is good and that connections are secure both at the antenna distribution center and at the OAT100R Fix and verify as necessary Ensure the antenna is pointed so as to achieve the best signal quality Ensure the signal level at...

Page 70: ... OAT100R System Status via GUI or System Monitor via command line display and observe the system configuration data Redisplay the OAT100R System Status via GUI or System Monitor via command line and check the ouput bitrates for each tuner For each tuner access the Tuner Menu via GUI or Tuner Information display via command line and make sure at least one program is enabled for each tuner channel N...

Page 71: ...c If the amber LED is blinking there is intermittent traffic but no streaming Use the appropriate steps depending on the output mode to help determine if and where there is an issue in the network To verify OAT100R RF output Use a spectrum analyzer to observe the RF OUT port on the OAT100R rear panel The channel power should be approximately 6 dBm 42 dBmV and the 6 MHz modulation channel should be...

Page 72: ... Celsius 32 to 104 Fahrenheit Humidity 95 non condensing Electrical RF Out Connector Type F RF Output Span 4 Contiguous Channels typically 24 MHz RF Output Frequency Range 54 MHz to 864 MHz Active Output Level at RF Out jack 6 dBm 42 dBmV Min RF IN Ports 8 Type F 75 Ohm RF Input Frequency Range Terrestrial Channels 2 to 69 RF Input Signal Level 3 dBm 52 dBmV to 83 dBm 34 dBmV DC Input 12V DC 2 6 A...

Page 73: ...t Revision History Notes Notes Document Revision History Date Description October 2012 Revision A New document January 2013 Revision B Features list update Product documentation is available online at www LGsolutions com ...

Page 74: ...Copyright 2000 2001 Corinna Vinschen Copyright 2002 Cray Inc Wendy Palm Copyright 2000 Denis Parker Copyright 2001 Gert Doering Copyright 2001 2003 Jakob Schlyter Copyright 1996 Jason Downs Copyright 2002 Juha Yrjölä Copyright 2000 Michael Stone Copyright 2002 Networks Associates Technology Inc Copyright 1997 1998 2000 2002 2004 Todd C Miller Copyright 2003 2004 2005 Darren Tucker Copyright 1988 2...

Page 75: ...NTY EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND LG SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INDIRECT OR INCIDENTAL DAMAGES OF ANY KIND INCLUDING LOST REVENUES OR PROFITS IN CONNECTION WITH THIS PRODUCT SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL O...

Reviews: