33
206-4218
Example: IP Output Configuration Fields
Complete output configuration as follows:
1. Select the Output Mode—RF or IP—by clicking the radio button at the left of the appropriate
option.
Note:
Depending on the current configuration of the system, when you access the System
Setup screen, either the RF Output Configuration or IP Output Configuration fields initially
will be on display below the Output Mode options. If you select a new mode, the system will
display the applicable fields per your selection.
2. The next step depends on the output mode selected:
• RF output configuration: First, select the RF Mode—64-QAM or 256-QAM (default)—by
clicking the radio button at the left of the appropriate option. Then, in the Start RF Channel
field, type the RF start channel number. The remaining three channels will be automatically
assigned per EIA-542 STD CATV frequency allocation standards.
• IP output configuration: For each IP channel stream, type the appropriate multicast IP
address and port number in the IP Address and IP Port fields, respectively.
Note:
If you would like the OAT100R to auto-increment IP channels from a base multicast
IP address, you will need to complete output IP channel configuration from the command
line interface. See “Configure the IP Output” on pages 56 to 58 for further information.
3. When you have completed the fields as required, click on the
Set
button below the Start RF
Channel field or below the last IP Port field, as applicable.
If you successfully changed output configuration parameters, the system will display
at the bottom of the System Information display. The System Information display will also show
the updated output configuration.
Configuration Options via GUI (Cont.)