40
206-4218
View System Information
1. Log in to the OAT100R as described on the previous page.
2. At the
Command >
prompt, type
info
and press
Enter
.
The System Information display identifies important information about the OAT100R,
including the unit serial number, software version, hardware ID (firmware version), Control
Port MAC and IP addresses, and output configuration, for example:
OAT100R
CodePlus Off Air Transcoder System
Copyright (c) 2010-2012 LG Electronics U.S.A, Inc.
Copyright (c) 2010-2012 Zenith Electronics LLC
Location:
Chicago, IL
SN:
201-12301011
Version
1.9
HW id:
12-19
Ctrl MAC:
00:0C:63:3A:FF:EC
Ctrl IP:
10.166.60.92
Program PIDs:
0x30 - 0x6f
Output:
RF
RF config:
Mode 2, 256-QAM-B, RF: 6 MHz, 5.36 MSps
RF channels:
2 3 4 5
Local time:
Wed Oct 17 14:42:02 CDT 2012
Note:
If the system is configured for IP output, the Output field will show “IP” and RF fields will
not be present. Also, the Location field is only present if the site location has been specified
either in the GUI System Setup screen or in the command line interface Setup Menu.
It is recommended that you record this information for future reference. If you find it
necessary to call customer service or engineering support, please have this information
available.
Monitor the System
This option enables you to view static or dynamic system streaming data.
1. Log in to the OAT100R as described on the previous page.
2. At the
Command >
prompt, either:
• Type
monitor
and press
Enter
to display the current system data (see example on
following page).
• To monitor streaming data in real time, type
monitor
and the number of seconds before
the data refreshes. Then, press
Enter
. For example, to refresh the data every second,
type
monitor 1
and press
Enter
.
When you are finished monitoring streaming data, press
Enter
to stop the system
monitor and return to the
Command >
prompt.
Configuration Options via Command Line (Cont.)