The products without the logo may not meet the ENERGY STAR® guidelines.
Temperature information
Operating temperature and relative humidity
10 to 32.2°C (50 to 90°F) and 15 to 80% RH
15.3 to 32.2°C (60 to 90°F) and 8 to 80% RH
Maximum wet bulb temperature
2
: 22.8°C (73°F)
Non-condensing environment
Printer / cartridge / imaging unit long-
term storage
1
Printer / cartridge / imaging unit short-term
shipping
-40 to 43.3°C (-40 to 110°F)
1
Supplies shelf life is approximately 2 years. This is based on storage in a standard office environment at 22°C (72°F)
and 45% humidity.
2
Wet-bulb temperature is determined by the air temperature and the relative humidity.
Laser notice
The printer is certified in the U.S. to conform to the requirements of DHHS 21 CFR, Chapter I, Subchapter J for
Class I (1) laser products, and elsewhere is certified as a Class I laser product conforming to the requirements
of IEC 60825-1: 2014.
Class I laser products are not considered to be hazardous. The printer contains internally a Class IIIb (3b) AlGaInP
laser that is nominally 15 milliwatts operating in the wavelength region of 650–670 nanometers and enclosed
in a non-serviceable printhead assembly. The laser system and printer are designed so there is never any human
access to laser radiation above a Class I level during normal operation, user maintenance, or prescribed service
conditions.
Power consumption
Product power consumption
The following table documents the power consumption characteristics of the product.
Note:
Some modes may not apply to your product.
Mode
Description
Power consumption (Watts)
Printing
The product is generating hard
‑
copy output from electronic inputs.
One-sided: 530
Two-sided: 360
Copy
The product is generating hard
‑
copy output from hard
‑
copy original
documents.
485
Scan
The product is scanning hard
‑
copy documents.
28.5
Ready
The product is waiting for a print job.
High power usage: 27.5
Low power usage: 24.3
Sleep Mode The product is in a high
‑
level energy
‑
saving mode.
1.44
Hibernate
The product is in a low
‑
level energy
‑
saving mode.
0.2
Notices