Starting up the device - Configuration
Leuze electronic
BCL 604i
77
Parameter length
29 byte
Input data
None
Output data
None
Identifier string n (n = 1 … 5)
The identifier string defines both the identifier list for the segmentation and the passthrough filter for the
subsequent filtering.
The string may contain wildcards. That is, an arbitrary number of '?' are permitted as placeholders for an
arbitrary character at exactly that position.
Also permitted are '*' as placeholders for a character sequence of arbitrary length, and an 'x' if the char
-
acter at the respective position is to be deleted. There are a total of 5 identifier strings.
An identifier with less than 5 characters must be null terminated. However, if the identifier string consists
of exactly 5 characters, it does not have to be null terminated.
10.10.4Module 55 – String handling parameters
Description
This module is used to configure placeholder characters for the bar code segmentation, filtering, termina
-
tion, and reference code processing.
Identifier 4
See identifier 1.
15
STRING
5 characters
null termi
-
nated
1 … 5 bytes of ASCII
characters
\0
-
Identifier 5
See identifier 1.
20
STRING
5 characters
null termi
-
nated
1 … 5 bytes of ASCII
characters
\0
-
Identifier output
Output with identi
-
fier
If this switch is not set, the output of the identi
-
fiers is suppressed. Only the data values that
belong to the identifiers are displayed in this
case.
25.0
Bit
0: Output of the identifiers
is suppressed.
1: Identifiers are output.
1
-
Output delimiter
This delimiter, if not equal to 0, is inserted
between the identifier and the associated data
value in the output.
26
UNSIGNED8
0 … 127
0
-
Segmentation acc. to identifier and separator
Identifier length
Fixed length of all identifiers in the segmenta
-
tion process. After this length, the text of the
identifier ends and the associated data value
starts. The end of the data value is determined
by the separator.
27
UNSIGNED8
0 … 255
0
-
Delimiter in the
identifier/separa
-
tor algorithm
The separator terminates the data value that
follows its identifier directly after the identifier
length. After the separator, the next identifier
starts.
28
UNSIGNED8
0 … 127
0
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit