Menu description
Leuze electronic
BCL 604i
42
Start auto-setup
The auto-setup function provides an easy option for configuring the code type and number of digits of
Decoder 1.
Use the enter button to activate the auto-setup function and hold an unknown bar code in the reading
beam of the device.
The following display appears:
The following information is displayed:
Start teach-in
The teach-in function can be used to conveniently read reference code 1.
Use the enter button to activate the teach-in function and hold a bar code which contains the content
that you wish to store as the reference code in the reading beam of the device.
The following display appears:
8.6
Operation
Shown here is an example describing important operating procedures in detail.
In this mode, the bar code reader must reach at least 100 identical readings to obtain the result.
The more readings are required, the lower the read quality.
The read quality is displayed via the bar graph.
xx
yy
zzzzzz
xx
Code type of the detected code (sets the code type of Decoder 1)
01
2/5 Interleaved
02
Code 39
03
Code 32
06
UPC (A, E)
07
EAN
08
Code 128, EAN 128
10
EAN Addendum
11
Codabar
12
Code 93
13
GS 1 Databar Omnidirectional
14
GS 1 Databar Limited
15
GS 1 Databar Expanded
yy
Number of digits of the detected code (sets the number of digits of Decoder 1)
zzzzzz
Contents of the decoded label. A appears if the label was not correctly read.
RC13xxzzzzzz
RC13
Means that ReferenceCode number 1 is stored in RAM. This is always output
xx
Defined code type (see auto-setup)
z
Defined code information (1 … 63 characters)